Analysis of adverse events related to extracorporeal membrane oxygenation from a nationwide database of patient-safety accidents in Japan.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Artificial Organs Pub Date : 2024-03-01 Epub Date: 2023-02-16 DOI:10.1007/s10047-023-01386-z
Hiroki Hadano, Tadashi Kamio, Kiyomitsu Fukaguchi, Mizuki Sato, Yumiko Tsunano, Hiroshi Koyama
{"title":"Analysis of adverse events related to extracorporeal membrane oxygenation from a nationwide database of patient-safety accidents in Japan.","authors":"Hiroki Hadano, Tadashi Kamio, Kiyomitsu Fukaguchi, Mizuki Sato, Yumiko Tsunano, Hiroshi Koyama","doi":"10.1007/s10047-023-01386-z","DOIUrl":null,"url":null,"abstract":"<p><p>Although adverse events related to extracorporeal membrane oxygenation have been reported, epidemiological data on life-threatening events are insufficient to study the causes of such adverse events. Data from the Japan Council for Quality Health Care database were retrospectively analyzed. The adverse events extracted from this national database included events associated with extracorporeal membrane oxygenation reported between January 2010 and December 2021. We identified 178 adverse events related to extracorporeal membrane oxygenation. At least 41 (23%) and 47 (26%) accidents resulted in death and residual disability, respectively. The most common adverse events were cannula malposition (28%), decannulation (19%), and bleeding (15%). Among patients with cannula malposition, 38% did not undergo fluoroscopy-guided or ultrasound-guided cannulation, 54% required surgical treatment, and 18% required trans-arterial embolization. In this epidemiological study in Japan, 23% of the adverse events related to extracorporeal membrane oxygenation had fatal outcomes. Our findings suggest that a training system for cannulation techniques may be needed, and hospitals offering extracorporeal membrane oxygenation should perform emergency surgeries.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9933024/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01386-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/2/16 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Although adverse events related to extracorporeal membrane oxygenation have been reported, epidemiological data on life-threatening events are insufficient to study the causes of such adverse events. Data from the Japan Council for Quality Health Care database were retrospectively analyzed. The adverse events extracted from this national database included events associated with extracorporeal membrane oxygenation reported between January 2010 and December 2021. We identified 178 adverse events related to extracorporeal membrane oxygenation. At least 41 (23%) and 47 (26%) accidents resulted in death and residual disability, respectively. The most common adverse events were cannula malposition (28%), decannulation (19%), and bleeding (15%). Among patients with cannula malposition, 38% did not undergo fluoroscopy-guided or ultrasound-guided cannulation, 54% required surgical treatment, and 18% required trans-arterial embolization. In this epidemiological study in Japan, 23% of the adverse events related to extracorporeal membrane oxygenation had fatal outcomes. Our findings suggest that a training system for cannulation techniques may be needed, and hospitals offering extracorporeal membrane oxygenation should perform emergency surgeries.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
日本全国患者安全事故数据库中与体外膜氧合相关的不良事件分析。
尽管与体外膜氧合相关的不良事件时有报道,但有关危及生命事件的流行病学数据不足以研究此类不良事件的原因。我们对日本医疗质量委员会数据库中的数据进行了回顾性分析。从该国家数据库中提取的不良事件包括2010年1月至2021年12月期间报告的与体外膜氧合相关的事件。我们发现了 178 起与体外膜氧合相关的不良事件。至少有 41 起(23%)和 47 起(26%)分别导致死亡和残留残疾。最常见的不良事件是插管错位(28%)、拔管(19%)和出血(15%)。在插管错位的患者中,38%没有在透视或超声引导下插管,54%需要手术治疗,18%需要经动脉栓塞。在日本的这项流行病学研究中,与体外膜肺氧合相关的不良事件中有 23% 导致死亡。我们的研究结果表明,可能需要建立一个插管技术培训系统,提供体外膜氧合的医院应进行紧急手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
期刊最新文献
Exploring the role of plasmapheresis prior to thyroidectomy in managing thyrotoxicosis: a comprehensive scoping review. A compact machine perfusion device for whole blood perfusion in isolated rat liver. Advanced roll porous scaffold 3D bioprinting technology. Impact of the spleen size on short-term prognosis in patients with cardiogenic shock receiving Impella-incorporated temporary mechanical circulatory support Axial-flow polymer bridge pump with hydrodynamic bearings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1