{"title":"Comparison of novel anteroposterior short-axis in-plane technique with conventional short-axis out-of-plane technique for ultrasound-guided internal jugular vein cannulation: A randomized-controlled trial.","authors":"Karma Ongmu Bhutia, Ankur Sharma, Shilpa Goyal, Nikhil Kothari, Kamlesh Kumari, Akhil Dhanesh Goel, Priyanka Sethi, Pradeep Bhatia","doi":"10.4103/2452-2473.366485","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Various ultrasound (US)-guided probe positioning and needle procedures have been described in the literature for cannulation of the internal jugular vein (IJV). In the present study, we compared the conventional short-axis out-of-plane (SAX-OOP) method with a novel anteroposterior short-axis in-plane (APSAX-IP) technique for IJV cannulation under US guidance. The APSAX-IP method of IJV cannulation has not been compared to other IJV cannulation techniques.</p><p><strong>Methods: </strong>A total of 104 patients above 18-year-old were randomly allocated to one of two groups - APSAX-IP or SAX-OOP and evaluated for US-guided IJV cannulation in either the operating room or critical care unit. The primary outcome of this research was the access time for IJV cannulation using both approaches. The secondary outcomes were the number of attempts of needle insertion, success rate, and complications of IJV cannulation.</p><p><strong>Results: </strong>The access time for IJV cannulation was 13.0 (12.0-15.0) sec in the APSAX-IP group and 13.0 (12.0-14.0) sec in the SAX-OOP group; <i>P</i> = 0.947. The number of successful 1<sup>st</sup> attempts was 90.91%, and the 2<sup>nd</sup> attempts were 9.09% in the APSAX-IP group and 85.19% and 14.81% in the SAX-OOP group, respectively. Both techniques did not have any complications.</p><p><strong>Conclusions: </strong>We conclude that the US-guided APSAX-IP IJV cannulation method has comparable access time to the SAX-OOP technique.</p>","PeriodicalId":46536,"journal":{"name":"Turkish Journal of Emergency Medicine","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ad/ac/TJEM-23-17.PMC9930384.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Emergency Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/2452-2473.366485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Various ultrasound (US)-guided probe positioning and needle procedures have been described in the literature for cannulation of the internal jugular vein (IJV). In the present study, we compared the conventional short-axis out-of-plane (SAX-OOP) method with a novel anteroposterior short-axis in-plane (APSAX-IP) technique for IJV cannulation under US guidance. The APSAX-IP method of IJV cannulation has not been compared to other IJV cannulation techniques.
Methods: A total of 104 patients above 18-year-old were randomly allocated to one of two groups - APSAX-IP or SAX-OOP and evaluated for US-guided IJV cannulation in either the operating room or critical care unit. The primary outcome of this research was the access time for IJV cannulation using both approaches. The secondary outcomes were the number of attempts of needle insertion, success rate, and complications of IJV cannulation.
Results: The access time for IJV cannulation was 13.0 (12.0-15.0) sec in the APSAX-IP group and 13.0 (12.0-14.0) sec in the SAX-OOP group; P = 0.947. The number of successful 1st attempts was 90.91%, and the 2nd attempts were 9.09% in the APSAX-IP group and 85.19% and 14.81% in the SAX-OOP group, respectively. Both techniques did not have any complications.
Conclusions: We conclude that the US-guided APSAX-IP IJV cannulation method has comparable access time to the SAX-OOP technique.
期刊介绍:
The Turkish Journal of Emergency Medicine (Turk J Emerg Med) is an International, peer-reviewed, open-access journal that publishes clinical and experimental trials, case reports, invited reviews, case images, letters to the Editor, and interesting research conducted in all fields of Emergency Medicine. The Journal is the official scientific publication of the Emergency Medicine Association of Turkey (EMAT) and is printed four times a year, in January, April, July and October. The language of the journal is English. The Journal is based on independent and unbiased double-blinded peer-reviewed principles. Only unpublished papers that are not under review for publication elsewhere can be submitted. The authors are responsible for the scientific content of the material to be published. The Turkish Journal of Emergency Medicine reserves the right to request any research materials on which the paper is based. The Editorial Board of the Turkish Journal of Emergency Medicine and the Publisher adheres to the principles of the International Council of Medical Journal Editors, the World Association of Medical Editors, the Council of Science Editors, the Committee on Publication Ethics, the US National Library of Medicine, the US Office of Research Integrity, the European Association of Science Editors, and the International Society of Managing and Technical Editors.