Personal dose equivalent Hp(0.07) during 68Ga-DOTA-TATE production procedures.

IF 1.5 4区 环境科学与生态学 Q3 BIOLOGY Radiation and Environmental Biophysics Pub Date : 2023-03-01 Epub Date: 2023-01-10 DOI:10.1007/s00411-022-01015-y
M Wrzesień, Ł Albiniak
{"title":"Personal dose equivalent H<sub>p</sub>(0.07) during <sup>68</sup>Ga-DOTA-TATE production procedures.","authors":"M Wrzesień, Ł Albiniak","doi":"10.1007/s00411-022-01015-y","DOIUrl":null,"url":null,"abstract":"<p><p>This work presents the exposure of hands of the personnel of a nuclear medicine department who prepare and administer <sup>68</sup>Ga-DOTA-TATE. Dosimetry measurements were performed during three 1-week sessions, for nine production procedures. A total of 360 measurements were made by using high-sensitivity MCP-N thermoluminescent detectors. Annealed detectors were and vacuum-packed in foil and then placed on each fingertip of both hands of five radiochemists and four nurses (one detector for one fingertip). The greatest exposure to ionizing radiation was found on the non-dominant left hand of radiochemists and nurses. A maximum H<sub>p</sub>(0.07)/A value of 49.36 ± 4.95 mSv/GBq was registered for radiochemists during the <sup>68</sup> Ga-DOTA-DATE activity dispensing procedure. For nurses performing the radiopharmaceutical injection procedure, a corresponding maximum value of 1.28 ± 0.13 mSv/GBq was measured, while the mean value for all the nurses was 0.38 mSv/GBq. The dispensing procedure accounted for approximately 60% of the total exposure of radiochemists' fingertips. Based on the results obtained it is recommended that a ring dosimeter should be routinely placed on the middle finger of the non-dominant hand of radiochemists and nurses. Furthermore, it is proposed to systematically train workers in handling open sources of ionizing radiation, with the aim of reducing the required handling time.</p>","PeriodicalId":21002,"journal":{"name":"Radiation and Environmental Biophysics","volume":"62 1","pages":"117-129"},"PeriodicalIF":1.5000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9950246/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation and Environmental Biophysics","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1007/s00411-022-01015-y","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents the exposure of hands of the personnel of a nuclear medicine department who prepare and administer 68Ga-DOTA-TATE. Dosimetry measurements were performed during three 1-week sessions, for nine production procedures. A total of 360 measurements were made by using high-sensitivity MCP-N thermoluminescent detectors. Annealed detectors were and vacuum-packed in foil and then placed on each fingertip of both hands of five radiochemists and four nurses (one detector for one fingertip). The greatest exposure to ionizing radiation was found on the non-dominant left hand of radiochemists and nurses. A maximum Hp(0.07)/A value of 49.36 ± 4.95 mSv/GBq was registered for radiochemists during the 68 Ga-DOTA-DATE activity dispensing procedure. For nurses performing the radiopharmaceutical injection procedure, a corresponding maximum value of 1.28 ± 0.13 mSv/GBq was measured, while the mean value for all the nurses was 0.38 mSv/GBq. The dispensing procedure accounted for approximately 60% of the total exposure of radiochemists' fingertips. Based on the results obtained it is recommended that a ring dosimeter should be routinely placed on the middle finger of the non-dominant hand of radiochemists and nurses. Furthermore, it is proposed to systematically train workers in handling open sources of ionizing radiation, with the aim of reducing the required handling time.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
68Ga-DOTA-TATE 生产过程中的个人剂量当量 Hp(0.07)。
本研究介绍了核医学部门制备和施用 68Ga-DOTA-TATE 的人员的手部暴露情况。在三个为期一周的会议期间,对九个生产程序进行了剂量测定。使用高灵敏度 MCP-N 热释光探测器共进行了 360 次测量。退火后的探测器用铝箔真空包装,然后分别贴在五名放射化学家和四名护士的双手指尖上(一个指尖一个探测器)。放射化学家和护士的非惯用左手受到的电离辐射最大。在 68 Ga-DOTA-DATE 放射性活度分配过程中,放射化学家的最高 Hp(0.07)/A 值为 49.36 ± 4.95 mSv/GBq。对于执行放射性药物注射程序的护士,测得的相应最大值为 1.28 ± 0.13 mSv/GBq,而所有护士的平均值为 0.38 mSv/GBq。配药过程约占放射化学家指尖总暴露量的 60%。根据所得结果,建议将环形剂量计常规放置在放射化学家和护士非惯用手的中指上。此外,建议对工作人员进行处理开放式电离辐射源的系统培训,以减少所需的处理时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.00
自引率
5.90%
发文量
53
审稿时长
>36 weeks
期刊介绍: This journal is devoted to fundamental and applied issues in radiation research and biophysics. The topics may include: Biophysics of ionizing radiation: radiation physics and chemistry, radiation dosimetry, radiobiology, radioecology, biophysical foundations of medical applications of radiation, and radiation protection. Biological effects of radiation: experimental or theoretical work on molecular or cellular effects; relevance of biological effects for risk assessment; biological effects of medical applications of radiation; relevance of radiation for biosphere and in space; modelling of ecosystems; modelling of transport processes of substances in biotic systems. Risk assessment: epidemiological studies of cancer and non-cancer effects; quantification of risk including exposures to radiation and confounding factors Contributions to these topics may include theoretical-mathematical and experimental material, as well as description of new techniques relevant for the study of these issues. They can range from complex radiobiological phenomena to issues in health physics and environmental protection.
期刊最新文献
Comment on "The scientific nature of the linear no-threshold (LNT) model used in the system of radiological protection" by A. Wojcik and F. Zölzer. Relationships between protection and operational dosimetric quantities for external exposure to natural background radiation. Analytic and Monte Carlo calculations of dose-mean lineal energy for 1 MeV-1 GeV protons with application to radiation protection quality factor. Evaluating the biological impact of shelters on astronaut health during different solar particle events: a Geant4-DNA simulation study. Estimation of surface doses in the presence of an air gap under a bolus for a 6 MV clinical photon beam - a phantom study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1