Marginal Gap and Internal Fit of Fixed Dental Prostheses Fabricated Using Intraoral vs Extraoral Scanning: A Systematic Review and Meta-analysis.

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2023-01-01 DOI:10.11607/ijp.7634
Sunil Kumar Mishra, Rajvi Vikram Nahar, Nithin Kumar Sonnahalli, Ramesh Chowdhary
{"title":"Marginal Gap and Internal Fit of Fixed Dental Prostheses Fabricated Using Intraoral vs Extraoral Scanning: A Systematic Review and Meta-analysis.","authors":"Sunil Kumar Mishra,&nbsp;Rajvi Vikram Nahar,&nbsp;Nithin Kumar Sonnahalli,&nbsp;Ramesh Chowdhary","doi":"10.11607/ijp.7634","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the marginal gap and internal fit of fixed dental prostheses (FDPs) fabricated using intraoral vs extraoral scanning methods.</p><p><strong>Materials and methods: </strong>MEDLINE/PubMed and the Cochrane database were searched. The focused PICO question was: For the fabrication of FDPs, does an intraoral scanning technique result in a different marginal gap than an extraoral scanning technique? The secondary outcome assessed was internal fit. Studies were selected based on the inclusion criteria, and a meta-analysis was performed.</p><p><strong>Results: </strong>A total of 14 studies (10 in vitro and 4 in vivo) were included in the meta-analysis. Marginal gap in single crowns was evaluated in 5 studies, copings for single crowns in 5 studies, three-unit FDPs in 3 studies, and both single-crown and three-unit FDPs in 1 study. Significantly lower marginal gap was found with intraoral scanning compared to impression scanning (P < .001) and cast scanning (P < .001), and for impression scanning compared to cast scanning (P = .037). Internal fit was superior with intraoral scanning compared to impression scanning, and this difference was significant (P < .001). No significant differences were found in internal fit with cast scanning compared to intraoral or impression scanning. The mean marginal gap/internal fit was 188.3 μm/146.2 μm with intraoral scanning, 116.29 μm/168.2 μm with impression scanning, and 195.1 μm/229.1 μm with cast scanning.</p><p><strong>Conclusion: </strong>Marginal gap was lower with intraoral scanning than with impression scanning and cast scanning. Impression scanning showed less marginal gap than cast scanning. Internal fit with intraoral scanning was superior to impression scanning, but when compared to cast scanning, no difference was found.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 1","pages":"91-103"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7634","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the marginal gap and internal fit of fixed dental prostheses (FDPs) fabricated using intraoral vs extraoral scanning methods.

Materials and methods: MEDLINE/PubMed and the Cochrane database were searched. The focused PICO question was: For the fabrication of FDPs, does an intraoral scanning technique result in a different marginal gap than an extraoral scanning technique? The secondary outcome assessed was internal fit. Studies were selected based on the inclusion criteria, and a meta-analysis was performed.

Results: A total of 14 studies (10 in vitro and 4 in vivo) were included in the meta-analysis. Marginal gap in single crowns was evaluated in 5 studies, copings for single crowns in 5 studies, three-unit FDPs in 3 studies, and both single-crown and three-unit FDPs in 1 study. Significantly lower marginal gap was found with intraoral scanning compared to impression scanning (P < .001) and cast scanning (P < .001), and for impression scanning compared to cast scanning (P = .037). Internal fit was superior with intraoral scanning compared to impression scanning, and this difference was significant (P < .001). No significant differences were found in internal fit with cast scanning compared to intraoral or impression scanning. The mean marginal gap/internal fit was 188.3 μm/146.2 μm with intraoral scanning, 116.29 μm/168.2 μm with impression scanning, and 195.1 μm/229.1 μm with cast scanning.

Conclusion: Marginal gap was lower with intraoral scanning than with impression scanning and cast scanning. Impression scanning showed less marginal gap than cast scanning. Internal fit with intraoral scanning was superior to impression scanning, but when compared to cast scanning, no difference was found.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用口内与口外扫描制作固定义齿的边缘间隙和内部配合:系统回顾和荟萃分析。
目的:比较口腔内扫描和口腔外扫描制备的固定义齿的边缘间隙和内配合度。材料和方法:检索MEDLINE/PubMed和Cochrane数据库。重点PICO问题是:对于fdp的制造,口内扫描技术与口外扫描技术是否会产生不同的边缘间隙?评估的次要结局为内部拟合。根据纳入标准选择研究,并进行meta分析。结果:荟萃分析共纳入14项研究(10项体外研究和4项体内研究)。5项研究评估了单冠的边缘间隙,5项研究评估了单冠的边缘间隙,3项研究评估了3个单位fdp, 1项研究评估了单冠和3个单位fdp。与印模扫描(P < 0.001)和铸型扫描(P < 0.001)相比,口内扫描的边缘间隙明显更小,与铸型扫描相比,印模扫描的边缘间隙明显更小(P = 0.037)。与印模扫描相比,口腔内扫描的内契合度更好,差异有统计学意义(P < 0.001)。与口内或印模扫描相比,铸型扫描在内配合方面没有明显差异。口腔内扫描的平均边缘间隙/内配合度为188.3 μm/146.2 μm,印模扫描为116.29 μm/168.2 μm,铸型扫描为195.1 μm/229.1 μm。结论:口腔内扫描比印模扫描和铸型扫描的边缘间隙小。印模扫描的边缘间隙小于铸型扫描。内吻合口内扫描优于印模扫描,但与铸型扫描相比,无差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1