{"title":"A case of insulinoma-induced hypoglycemia managed by Dexcom G4 Platinum.","authors":"Naoki Yamaguchi, Eijiro Yamada, Shunichi Matsumoto, Yasuyo Nakajima, Sumihito Nobusawa, Hideaki Yokoo, Sho Sekiguchi, Satoshi Yoshino, Kazuhiko Horiguchi, Emi Ishida, Shuichi Okada, Masanobu Yamada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabThis report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabetes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.etes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabThis report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabetes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.etes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.