Influence of the sampling technique on the measurement of peritoneal fibrinolytic activity

J. Neudecker, T. Junghans, S. Ziemer, W. Raue, W. Schwenk M.D.
{"title":"Influence of the sampling technique on the measurement of peritoneal fibrinolytic activity","authors":"J. Neudecker,&nbsp;T. Junghans,&nbsp;S. Ziemer,&nbsp;W. Raue,&nbsp;W. Schwenk M.D.","doi":"10.1002/ejs.6161681113","DOIUrl":null,"url":null,"abstract":"<p><i>Objective:</i> To establish the influence of the peritoneal sampling technique on the measurement of fibrinolytic capacity.</p><p><i>Design:</i> Clinical study.</p><p><i>Setting:</i> University hospital, Germany.</p><p><i>Subjects:</i> 40 peritoneal biopsy specimens were taken from 10 patients who were having elective colorectal resections.</p><p><i>Interventions:</i> Peritoneal biopsy specimens were taken either with a biopsy punch (<i>n</i> = 20) or manually with forceps and scissors (<i>n</i> = 20).</p><p><i>Main outcome measures:</i> Extent of agreement in fibrinolytic activities between specimens taken with biopsy punch and manually. Major endpoint—peritoneal tissue plasminogen activator (t-PA) activity. Minor endpoints—peritoneal tissue plasminogen activator concentration, and concentration and activity of plasminogen activator inhibitior type 1 (PAI-1).</p><p><i>Results:</i> Intra-assay agreement and the extent of agreement between the groups were evaluated by the method of Bland and Altman. Correlation of repeated measurements of t-PA and PAI-1 concentrations and activities from the same sample using the same ELISA kit was high (<i>r</i> = 0.93–0.99, <i>p</i> &lt; 0.01). t-PA activities and concentrations between the groups correlated poorly (<i>r</i> = 0.60 and 0.66, <i>p</i> &lt; 0.01) while no correlation at all was seen for PAI-1 concentration and activity between the groups (<i>r</i> = 0.6 and 0.1, <i>p</i> = 0.2 and 0.9). The mean differences between the groups ranged from −27% to −4.8%.</p><p><i>Conclusion:</i> The sampling technique considerably affects the measurement of peritoneal fibrinolytic activity.</p>","PeriodicalId":100508,"journal":{"name":"European Journal of Surgery","volume":"168 11","pages":"635-640"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ejs.6161681113","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Surgery","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ejs.6161681113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To establish the influence of the peritoneal sampling technique on the measurement of fibrinolytic capacity.

Design: Clinical study.

Setting: University hospital, Germany.

Subjects: 40 peritoneal biopsy specimens were taken from 10 patients who were having elective colorectal resections.

Interventions: Peritoneal biopsy specimens were taken either with a biopsy punch (n = 20) or manually with forceps and scissors (n = 20).

Main outcome measures: Extent of agreement in fibrinolytic activities between specimens taken with biopsy punch and manually. Major endpoint—peritoneal tissue plasminogen activator (t-PA) activity. Minor endpoints—peritoneal tissue plasminogen activator concentration, and concentration and activity of plasminogen activator inhibitior type 1 (PAI-1).

Results: Intra-assay agreement and the extent of agreement between the groups were evaluated by the method of Bland and Altman. Correlation of repeated measurements of t-PA and PAI-1 concentrations and activities from the same sample using the same ELISA kit was high (r = 0.93–0.99, p < 0.01). t-PA activities and concentrations between the groups correlated poorly (r = 0.60 and 0.66, p < 0.01) while no correlation at all was seen for PAI-1 concentration and activity between the groups (r = 0.6 and 0.1, p = 0.2 and 0.9). The mean differences between the groups ranged from −27% to −4.8%.

Conclusion: The sampling technique considerably affects the measurement of peritoneal fibrinolytic activity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
取样技术对腹膜纤溶活性测定的影响
目的:探讨腹膜取样技术对测定纤溶能力的影响。设计:临床研究。地点:德国大学医院。研究对象:从10例择期结肠切除术患者中取出40例腹膜活检标本。干预措施:采用活检打孔机(n = 20)或手工用镊子和剪刀(n = 20)采集腹膜活检标本。主要结果测量:活检打孔法和手工法取样的纤维蛋白溶解活性的一致程度。主要终点:腹膜组织纤溶酶原激活物(t-PA)活性。次要终点-腹膜组织纤溶酶原激活剂浓度,以及1型纤溶酶原激活剂抑制(PAI-1)的浓度和活性。结果:采用Bland和Altman法评价组内一致性和组间一致性程度。使用相同ELISA试剂盒对同一样品重复测定t-PA和PAI-1浓度与活性的相关性很高(r = 0.93-0.99, p <0.01)。各组间t-PA活性和浓度相关性较差(r = 0.60和0.66,p <各组间PAI-1浓度和活性无相关性(r = 0.6和0.1,p = 0.2和0.9)。两组间的平均差异为- 27%至- 4.8%。结论:取样技术对腹膜纤溶活性测定有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Masthead Masthead Masthead Importance of the early increase in intestinal permeability in critically Ill patients Prospective evaluation of laparoscopic and open 360° fundoplication in mild and severe gastro-oesophageal reflux disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1