Display technology for radiology

M Weibrecht
{"title":"Display technology for radiology","authors":"M Weibrecht","doi":"10.1016/S0222-0776(00)88263-2","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>A brief overview on the operating principles of current display technologies, namely catho-de-ray-tube (CRT) monitors and active-matrix liquid crystal displays (AMLCD), will be given. Physical properties having major impact on the perceived image quality, and respective measurement procedures will be described. Based on this introduction, the results of the evaluation of several displays will be discussed.</p></div><div><h3>Materials and methods</h3><p>The luminance output of displays, veiling glare, and reflected ambient light were measured with a high precision photometer by LMT (L1003). Resolution measurements were performed with a scientific CCD camera system. The images of the CCD camera were object to various calibration procedures and feature extraction algorithms developed at Aachen.</p></div><div><h3>Results</h3><p>The highest overall image quality is provided by monochrome CRT displays. However, the latest generation of LCDs is almost similar in terms of resolution. Yet, the LCD technology suffers from severe drawbacks in the gray-scale rendition.</p></div><div><h3>Conclusion</h3><p>Although LCD technology is developing very rapidly, it has not yet achieved the quality to replace standard displays based on CRTs. Standard computer monitors show least quality and require sophisticated image processing to be employed in medical imaging.</p></div>","PeriodicalId":101059,"journal":{"name":"RBM-News","volume":"21 7","pages":"Page 146"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0222-0776(00)88263-2","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RBM-News","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0222077600882632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

A brief overview on the operating principles of current display technologies, namely catho-de-ray-tube (CRT) monitors and active-matrix liquid crystal displays (AMLCD), will be given. Physical properties having major impact on the perceived image quality, and respective measurement procedures will be described. Based on this introduction, the results of the evaluation of several displays will be discussed.

Materials and methods

The luminance output of displays, veiling glare, and reflected ambient light were measured with a high precision photometer by LMT (L1003). Resolution measurements were performed with a scientific CCD camera system. The images of the CCD camera were object to various calibration procedures and feature extraction algorithms developed at Aachen.

Results

The highest overall image quality is provided by monochrome CRT displays. However, the latest generation of LCDs is almost similar in terms of resolution. Yet, the LCD technology suffers from severe drawbacks in the gray-scale rendition.

Conclusion

Although LCD technology is developing very rapidly, it has not yet achieved the quality to replace standard displays based on CRTs. Standard computer monitors show least quality and require sophisticated image processing to be employed in medical imaging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
放射学显示技术
目的简要介绍当前显示技术,即阴极射线管(CRT)显示器和有源矩阵液晶显示器(AMLCD)的工作原理。对感知图像质量有重大影响的物理特性,以及各自的测量程序将被描述。在此基础上,将讨论几种显示器的评估结果。材料和方法采用高精度光度计,通过LMT (L1003)测量显示器输出亮度、遮挡眩光和反射环境光。分辨率测量是用科学的CCD相机系统进行的。CCD相机的图像是亚琛开发的各种校准程序和特征提取算法的对象。结果单色CRT显示器提供了最高的整体图像质量。然而,最新一代的液晶显示器在分辨率方面几乎是相似的。然而,LCD技术在灰度呈现方面存在严重缺陷。结论LCD技术虽然发展迅速,但还没有达到取代基于crt的标准显示器的质量。标准的计算机显示器显示质量最低,并且需要复杂的图像处理才能用于医学成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Errata Évaluation de l'équilibre neurovégétatif chez le nourrisson Bug de l'an 2000, et après ?: Quels enseignements pour la matériovigilance ? Accréditation EN 45001 au service biomédical Systèmes de documentation informatisée de l'anesthésie (et de la réanimation)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1