{"title":"Chromium, cobalt and nickel in Swedish cement, detergents, mould and cutting oils.","authors":"J E Wahlberg, G Lindstedt, O Einarsson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The concentrations of chromium, cobalt and nickel in 8 brands of Swedish cement, 19 detergents, 28 unused mould oils and 28 unused cutting fluids were determined by atomic absorption spectrophotometry. The total quantity of chromium in cement was 40-115 microgram Cr/g, whereas water-soluble chromium and chromate did not exceed 20 microgram Cr/g. The cobalt concentration was 5-16 microgram Co/g and the nickel concentration 5-59 microgram Ni/g. In detergents the nickel concentration was comparatively higher than that of chromium and cobalt. The highest value observed was 5.7 microgram Ni/g. In mould oils the concentrations were low, never exceeding 1 microgram/g. In cutting fluids the concentrations were low with the exeption of one product which contained 19.4 microgram Ni/g. The clinical implications of the results are discussed and it is pointed out that investigations of used cutting fluids can provide important information concerning possible allergy risks.</p>","PeriodicalId":8796,"journal":{"name":"Berufs-Dermatosen","volume":"25 6","pages":"220-8"},"PeriodicalIF":0.0000,"publicationDate":"1977-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Berufs-Dermatosen","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The concentrations of chromium, cobalt and nickel in 8 brands of Swedish cement, 19 detergents, 28 unused mould oils and 28 unused cutting fluids were determined by atomic absorption spectrophotometry. The total quantity of chromium in cement was 40-115 microgram Cr/g, whereas water-soluble chromium and chromate did not exceed 20 microgram Cr/g. The cobalt concentration was 5-16 microgram Co/g and the nickel concentration 5-59 microgram Ni/g. In detergents the nickel concentration was comparatively higher than that of chromium and cobalt. The highest value observed was 5.7 microgram Ni/g. In mould oils the concentrations were low, never exceeding 1 microgram/g. In cutting fluids the concentrations were low with the exeption of one product which contained 19.4 microgram Ni/g. The clinical implications of the results are discussed and it is pointed out that investigations of used cutting fluids can provide important information concerning possible allergy risks.