The Impact of a Building Implosion on Ambient Air Quality: A Case Study in an Urban Coastal City

B. G, Anju Farhana C
{"title":"The Impact of a Building Implosion on Ambient Air Quality: A Case Study in an Urban Coastal City","authors":"B. G, Anju Farhana C","doi":"10.47363/jeesr/2021(3)142","DOIUrl":null,"url":null,"abstract":"This study was carried out to assess the impact of implosion of four multi-storied apartments in an urban coastal city, Kochi, India on the ambient air quality. Air quality monitoring was conducted pre and post demolition stages indicated that there was short-term air quality deterioration surrounding the demolition sites. The increase of SPM, PM10 and PM2.5 was above the permissible limits during demolition which reduced afterwards, but was above the ambient level monitored in the pre demolition stage. In the case of SPM the concentration increased to 3004µgm/m3 during implosion in one of the sites, Golden Kayaloram. This site showed PM10 and PM2.5 also to be above permissible limits during implosion. This is followed by the monitoring sites of Jain Coral Cove, which also showed higher concentration levels above permissible limit during demolition. Other apartments, Alfa Serene and Holyfaith share the same monitoring sites and exceeds permissible limit for SPM and PM2.5 during demolition. In general more sites reported concentration above permissible limits for PM2.5. The average air quality after three months of implosion shows that, the pollutant concentration was much higher than the pre-demolition level. These results clearly show that building implosion is having severe impact on local air quality","PeriodicalId":417186,"journal":{"name":"Journal of Earth and Environmental Sciences Research","volume":"210 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Earth and Environmental Sciences Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47363/jeesr/2021(3)142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study was carried out to assess the impact of implosion of four multi-storied apartments in an urban coastal city, Kochi, India on the ambient air quality. Air quality monitoring was conducted pre and post demolition stages indicated that there was short-term air quality deterioration surrounding the demolition sites. The increase of SPM, PM10 and PM2.5 was above the permissible limits during demolition which reduced afterwards, but was above the ambient level monitored in the pre demolition stage. In the case of SPM the concentration increased to 3004µgm/m3 during implosion in one of the sites, Golden Kayaloram. This site showed PM10 and PM2.5 also to be above permissible limits during implosion. This is followed by the monitoring sites of Jain Coral Cove, which also showed higher concentration levels above permissible limit during demolition. Other apartments, Alfa Serene and Holyfaith share the same monitoring sites and exceeds permissible limit for SPM and PM2.5 during demolition. In general more sites reported concentration above permissible limits for PM2.5. The average air quality after three months of implosion shows that, the pollutant concentration was much higher than the pre-demolition level. These results clearly show that building implosion is having severe impact on local air quality
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
建筑内爆对环境空气质量的影响:以沿海城市为例
本研究旨在评估印度沿海城市高知市四栋多层公寓内爆对环境空气质量的影响。在拆卸前及拆卸后进行的空气质素监测显示,拆卸地点周围的空气质素有短期恶化。拆除过程中SPM、PM10和PM2.5的增幅均高于允许限值,拆除后有所下降,但仍高于拆除前监测的环境水平。在SPM的情况下,在其中一个地点Golden Kayaloram的内爆期间,浓度增加到3004µgm/m3。该站点显示,内爆期间PM10和PM2.5也高于允许限值。紧随其后的是耆那珊瑚湾的监测点,在拆卸过程中也显示出高于容许上限的浓度。其他公寓,阿尔法宁静和圣信共用同一个监测点,拆除时的SPM和PM2.5都超过了允许的上限。总体而言,报告PM2.5浓度超过允许限值的地点更多。爆破后3个月的平均空气质量表明,污染物浓度远高于爆破前水平。这些结果清楚地表明,建筑物内爆对当地空气质量产生了严重影响
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Migmatite-Gneiss-Granite Basement of Southwestern Nigeria: Mineralogical and Geochemical Evidence for a Possible Common Ancient Protolith Gravitational Radiation Induced Spiral-in Offsets the Pulsar Pair from its Final Lock-in Position- a New Metric for Relativistic Pulsar Binaries Physical Method Development for İncreasing EOR the Performances Wells The Economic Values of Coffea Arabica Biodiversity in Ethiopia A Fixed Bed Adsorption Column Study for Synthetic Dye Wastewater using Magnetic Biochar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1