{"title":"Improved condition assessment of XLPE insulated cables using the isothermal relaxation current technique","authors":"B. Oyegoke","doi":"10.1109/CEIDP.2006.311973","DOIUrl":null,"url":null,"abstract":"Well-known procedures using the isothermal relaxation current method (IRC) use an empirically-derived ageing factor (the A-factor) to estimate the condition of cables. The A-factor is calculated from plots of the product of instantaneous value of IRC and the time to that value from the start of the current, against the log of time. A-factors are computed from a standard formula using constants determined from curve fits of measured depolarization currents. From measurements of the breakdown strength of samples of real and degraded cables it has been found that A-factors do not provide reliable estimates of XLPE cable condition. However, if semi-conducting material of the cable insulation is known and cables are classified according to semi-conducting material type it is possible to get better correlation between conditions of cables as indicated by A-factors and AC breakdown voltage. This paper contains a novel analysis of result from previous researcher and also includes result from tests on other cables. The refined procedure is found to give reasonable value of A-factor for all cable tested.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"20 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2006.311973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Well-known procedures using the isothermal relaxation current method (IRC) use an empirically-derived ageing factor (the A-factor) to estimate the condition of cables. The A-factor is calculated from plots of the product of instantaneous value of IRC and the time to that value from the start of the current, against the log of time. A-factors are computed from a standard formula using constants determined from curve fits of measured depolarization currents. From measurements of the breakdown strength of samples of real and degraded cables it has been found that A-factors do not provide reliable estimates of XLPE cable condition. However, if semi-conducting material of the cable insulation is known and cables are classified according to semi-conducting material type it is possible to get better correlation between conditions of cables as indicated by A-factors and AC breakdown voltage. This paper contains a novel analysis of result from previous researcher and also includes result from tests on other cables. The refined procedure is found to give reasonable value of A-factor for all cable tested.