{"title":"Analysis of Grid Integrated PV System as Home RES with Net Metering Scheme","authors":"Nazmus Saqib, Khandaker Foysal Haque, Rifat Zabin, Sayed Nahian Preonto","doi":"10.1109/ICREST.2019.8644098","DOIUrl":null,"url":null,"abstract":"To meet the increased demand of electricity, PV system is being used as home RES (Renewable Energy Source) throughout the world. In this paper, a grid integrated PV system has been proposed with net metering scheme. A home of 149 sq. meter in Dhaka city is considered whose average daily load is 11.27 kWh/day with an annual peak load of 1.21 kW. According to DESCO (Dhaka Electric Supply Company Limited), for the span of last one year (July, 2017-July, 2018) the monthly electricity usage of this home varies from 401-600 units (kWh) with a Cost of Energy (COE) of $0.1. Simulation and analysis of the proposed system shows that the Cost of Energy (COE) and Net present Cost (NPC) of the proposed system can be reduced to a great extent with the application of net metering scheme which also improves the renewable fraction of the system.","PeriodicalId":108842,"journal":{"name":"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Robotics,Electrical and Signal Processing Techniques (ICREST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICREST.2019.8644098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
To meet the increased demand of electricity, PV system is being used as home RES (Renewable Energy Source) throughout the world. In this paper, a grid integrated PV system has been proposed with net metering scheme. A home of 149 sq. meter in Dhaka city is considered whose average daily load is 11.27 kWh/day with an annual peak load of 1.21 kW. According to DESCO (Dhaka Electric Supply Company Limited), for the span of last one year (July, 2017-July, 2018) the monthly electricity usage of this home varies from 401-600 units (kWh) with a Cost of Energy (COE) of $0.1. Simulation and analysis of the proposed system shows that the Cost of Energy (COE) and Net present Cost (NPC) of the proposed system can be reduced to a great extent with the application of net metering scheme which also improves the renewable fraction of the system.