Analisis Fractography dan Kegagalan Fuel Injection Valve Diesel Power Plant PT.XYZ Area Bali

Andi Iriyanto
{"title":"Analisis Fractography dan Kegagalan Fuel Injection Valve Diesel Power Plant PT.XYZ Area Bali","authors":"Andi Iriyanto","doi":"10.33322/energi.v13i2.1336","DOIUrl":null,"url":null,"abstract":"To meet the electricity needs in tiga nusa, so far it has been served with an isolated grid system with Diesel Generators. To improve the reliability of Diesel Engines from Fuel Injection Valve interference is to test Fuel-Injection Valve whether or not meets the relevant specifications at certain condition to prevent repeated failures. On December 10, 2019 (Running Hours 15,505), there was a disturbance with an indication of a decrease in the temperature of the unit 1 cylinder, After inspection, it was found that there was no atomizing and the Fuel Injection Valve was cracked. The preparation of this report is carried out to find the root of the problem so that it can determine the right Failure Defense Task (FDT) to prevent the disturbance from reoccurring. \n ","PeriodicalId":166066,"journal":{"name":"ENERGI & KELISTRIKAN","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ENERGI & KELISTRIKAN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33322/energi.v13i2.1336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To meet the electricity needs in tiga nusa, so far it has been served with an isolated grid system with Diesel Generators. To improve the reliability of Diesel Engines from Fuel Injection Valve interference is to test Fuel-Injection Valve whether or not meets the relevant specifications at certain condition to prevent repeated failures. On December 10, 2019 (Running Hours 15,505), there was a disturbance with an indication of a decrease in the temperature of the unit 1 cylinder, After inspection, it was found that there was no atomizing and the Fuel Injection Valve was cracked. The preparation of this report is carried out to find the root of the problem so that it can determine the right Failure Defense Task (FDT) to prevent the disturbance from reoccurring.  
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
巴厘xyz地区柴油发电厂Kegagalan燃油喷射阀断口分析
为了满足提加努萨的电力需求,到目前为止,它一直使用一个带有柴油发电机的孤立电网系统。防止喷油阀干扰提高柴油机可靠性的方法是在一定条件下测试喷油阀是否满足相关规范要求,以防止重复故障的发生。2019年12月10日(运行小时15505),1号机组汽缸出现扰动,显示温度下降,经检查发现无雾化,喷油阀破裂。本报告的编写是为了找到问题的根源,以便确定正确的故障防御任务(FDT),以防止干扰再次发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimization of Lube Oil Cooler Fan at Reserve Shutdown Combined Cycle Power Plant Priok Pengaruh SVL Pada Metallic Sheat Underground Cable 150 kV Terhadap Transient Switching Capasitor Bank PLTU FTP 2 Lombok 2x50 MW Perancangan Sistem Monitoring Pada Pemilah Sampah Otomatis Berbasis Internet of Things Menggunakan Aplikasi Blynk Analisis Rancang Bangun Implementasi SCADA System Untuk Peningkatan Performa Mesin Produksi Pada Proses Washing Component Manufacture Engine Assembling Analisis Sistem Pencahayaan Pada Lantai 3 Gedung Kuliah Umum Institut Teknologi Sumatera
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1