Imaging performance of the Si/Ge hybrid Compton imager

M. Burks, D. Chivers, C. Cork, M. Cunningham, L. Fabris, D. Gunter, E. Hull, D. Lange, H. Manini, L. Mihailescu, K. Nelson, T. Niedermayr, J. Valentine, K. Vetter, D. Wright
{"title":"Imaging performance of the Si/Ge hybrid Compton imager","authors":"M. Burks, D. Chivers, C. Cork, M. Cunningham, L. Fabris, D. Gunter, E. Hull, D. Lange, H. Manini, L. Mihailescu, K. Nelson, T. Niedermayr, J. Valentine, K. Vetter, D. Wright","doi":"10.1109/NSSMIC.2005.1596196","DOIUrl":null,"url":null,"abstract":"The point spread function (PSF) of a fully-instrumented silicon/germanium Compton telescope has been measured as a function of energy and angle. Overall, the resolution was 3deg to 4deg FWHM over most of the energy range and field of view. The various contributions to the resolution have been quantified. These contributions include the energy and position uncertainty of the detector; source energy; Doppler broadening; and the 1/r broadening characteristic of Compton back-projection. Furthermore, a distortion of the PSF is observed for sources imaged off-axis from the detector. These contributions are discussed and compared to theory and simulations","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The point spread function (PSF) of a fully-instrumented silicon/germanium Compton telescope has been measured as a function of energy and angle. Overall, the resolution was 3deg to 4deg FWHM over most of the energy range and field of view. The various contributions to the resolution have been quantified. These contributions include the energy and position uncertainty of the detector; source energy; Doppler broadening; and the 1/r broadening characteristic of Compton back-projection. Furthermore, a distortion of the PSF is observed for sources imaged off-axis from the detector. These contributions are discussed and compared to theory and simulations
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Si/Ge混合康普顿成像仪的成像性能
测量了全仪器硅/锗康普顿望远镜的点扩展函数(PSF)作为能量和角度的函数。总的来说,在大部分能量范围和视场范围内,分辨率为3到4度FWHM。对决议的各种贡献已被量化。这些贡献包括探测器的能量和位置的不确定性;源能源;多普勒展宽;康普顿反投影的1/r展宽特性。此外,在探测器离轴成像的源处观察到PSF的畸变。对这些贡献进行了讨论,并与理论和模拟进行了比较
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Monte Carlo optimization of an industrial tomography system A scalable system for microcalcification cluster automated detection in a distributed mammographic database The BaBar muon system upgrade Fast, long-wavelength scintillators and waveshifters New effects observed in the BaBar silicon vertex tracker: interpretation and estimate of their impact on the future performance of the detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1