{"title":"Active Power Filter for Harmonic Mitigation of Power Quality Issues in Grid Integrated Photovoltaic Generation System","authors":"S. Agrawal, S. Vaishnav, Ajit, R. Somani","doi":"10.1109/SPIN48934.2020.9070979","DOIUrl":null,"url":null,"abstract":"Single phase supply scheme tied with Photovoltaic arrangement (PV) employed on perturbed & observed (P&O) maximum energy point tracking technique with shunt active power filter allied to a rectifier feed R-L nonlinear load. The traditional Perturbed & Observed technique maximum energy point tracking topology is applied to attained maximum output power from Photovoltaic array(PVA), Proportional Integral conventional controller with phase detector (PD) phase locked loop (PLL) synchronization are executed to produce reference current. It provide at control unit of pulse width modulation topology( PWM) is utilized in inverter to get steady output voltage. Self supported DC bus PWM converter is regulated from PV array. In proposed architecture is minimized total harmonic pollution existing in supply current owing to power electronic load (PEL). Total current harmonic pollution (THDi) is compensated using dynamic filter shunt active power filter (SAPF) and power factor obtain better later than compensation. Hence, reactive power (KVAR) is delivered through system decrease and active power (KW) enhance. The suggested scheme has been implemented by way of MATLAB/SIMULINK 2015(a) environment.","PeriodicalId":126759,"journal":{"name":"2020 7th International Conference on Signal Processing and Integrated Networks (SPIN)","volume":"179 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 7th International Conference on Signal Processing and Integrated Networks (SPIN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIN48934.2020.9070979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
Single phase supply scheme tied with Photovoltaic arrangement (PV) employed on perturbed & observed (P&O) maximum energy point tracking technique with shunt active power filter allied to a rectifier feed R-L nonlinear load. The traditional Perturbed & Observed technique maximum energy point tracking topology is applied to attained maximum output power from Photovoltaic array(PVA), Proportional Integral conventional controller with phase detector (PD) phase locked loop (PLL) synchronization are executed to produce reference current. It provide at control unit of pulse width modulation topology( PWM) is utilized in inverter to get steady output voltage. Self supported DC bus PWM converter is regulated from PV array. In proposed architecture is minimized total harmonic pollution existing in supply current owing to power electronic load (PEL). Total current harmonic pollution (THDi) is compensated using dynamic filter shunt active power filter (SAPF) and power factor obtain better later than compensation. Hence, reactive power (KVAR) is delivered through system decrease and active power (KW) enhance. The suggested scheme has been implemented by way of MATLAB/SIMULINK 2015(a) environment.