Current control of three-phase grid-connected PV inverters using adaptive PR controller

A. Althobaiti, M. Armstrong, M. Elgendy
{"title":"Current control of three-phase grid-connected PV inverters using adaptive PR controller","authors":"A. Althobaiti, M. Armstrong, M. Elgendy","doi":"10.1109/IREC.2016.7507628","DOIUrl":null,"url":null,"abstract":"In recent years, there has been a rapid increase in the number of grid connected three phase inverter systems being connected to the distribution network. As a result, the need for high quality, low harmonic distortion, current injection into the grid is essential. To achieve this, careful consideration of the inverter controller is necessary. Many control methods are based on the traditional proportional-integral controller (PI), or the more recently adopted Proportional Resonant controller (PR). This paper presents a new technique of minimizing the error of the current control in a three phase grid connected inverter using a readily implementable Adaptive Proportional Resonance controller. Simulation and experimental results demonstrate the effectiveness of the proposed technique.","PeriodicalId":190533,"journal":{"name":"2016 7th International Renewable Energy Congress (IREC)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 7th International Renewable Energy Congress (IREC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREC.2016.7507628","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

In recent years, there has been a rapid increase in the number of grid connected three phase inverter systems being connected to the distribution network. As a result, the need for high quality, low harmonic distortion, current injection into the grid is essential. To achieve this, careful consideration of the inverter controller is necessary. Many control methods are based on the traditional proportional-integral controller (PI), or the more recently adopted Proportional Resonant controller (PR). This paper presents a new technique of minimizing the error of the current control in a three phase grid connected inverter using a readily implementable Adaptive Proportional Resonance controller. Simulation and experimental results demonstrate the effectiveness of the proposed technique.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于自适应PR控制器的三相并网光伏逆变器电流控制
近年来,与配电网并网的三相逆变器系统数量迅速增加。因此,需要高质量、低谐波畸变的电流注入电网是必不可少的。要做到这一点,仔细考虑逆变器控制器是必要的。许多控制方法是基于传统的比例积分控制器(PI)或最近采用的比例谐振控制器(PR)。本文提出了一种利用易于实现的自适应比例谐振控制器来减小三相并网逆变器电流控制误差的新方法。仿真和实验结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative investigation on hill climbing MPPT algorithms at high perturbation rates Design of DC-DC converter for a grid connected inverter Predictive current control strategy for a three-phase grid connected photovoltaic-wind hybrid system Using quasi-static model for water/power management of a stand-alone wind/photovoltaic/BWRO desalination system without batteries Control strategy for small-scale photovoltaic systems connected to single-phase grids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1