Robust average current mode control of DC-DC PWM converters based on a three controller scheme

G. Garcerá, M. Pascual, E. Figueres
{"title":"Robust average current mode control of DC-DC PWM converters based on a three controller scheme","authors":"G. Garcerá, M. Pascual, E. Figueres","doi":"10.1109/ISIE.1999.798679","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present a drastic improvement in the conventional ACC (average current mode control) of switching DC-DC power converters, consisting of the addition of an auxiliary controller in the control loop, besides the current and voltage regulators. The model-based auxiliary controller preserves the closed loop small-signal bandwidth (including loop gain crossover frequency and stability margins) of buck derived converters over a large range of variation of the power stage passive elements, the load and the line voltage. Moreover, this control scheme shows much better perturbation rejection properties (closed loop impedance and audiosusceptibility) than conventional ACC. From a control theory point of view, robust performance is achieved preserving stability. A 5 V-5 A, 50 kHz buck prototype operating from an input voltage ranging from 30 V to 15 V has been experimentally tested with different LC output filters, line and load conditions, including discontinuous conduction mode. Measurements of the small signal frequency response of the converter (loop gain, closed loop audiosusceptibility and output impedance) have been carried out, showing the improvement achieved by the proposed control scheme. The empirical large signal response of the converter, under load steps, is also shown in this paper in order to validate the concept.","PeriodicalId":227402,"journal":{"name":"ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.1999.798679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

The purpose of this paper is to present a drastic improvement in the conventional ACC (average current mode control) of switching DC-DC power converters, consisting of the addition of an auxiliary controller in the control loop, besides the current and voltage regulators. The model-based auxiliary controller preserves the closed loop small-signal bandwidth (including loop gain crossover frequency and stability margins) of buck derived converters over a large range of variation of the power stage passive elements, the load and the line voltage. Moreover, this control scheme shows much better perturbation rejection properties (closed loop impedance and audiosusceptibility) than conventional ACC. From a control theory point of view, robust performance is achieved preserving stability. A 5 V-5 A, 50 kHz buck prototype operating from an input voltage ranging from 30 V to 15 V has been experimentally tested with different LC output filters, line and load conditions, including discontinuous conduction mode. Measurements of the small signal frequency response of the converter (loop gain, closed loop audiosusceptibility and output impedance) have been carried out, showing the improvement achieved by the proposed control scheme. The empirical large signal response of the converter, under load steps, is also shown in this paper in order to validate the concept.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于三控制器方案的DC-DC PWM变换器鲁棒平均电流模式控制
本文的目的是对传统的开关DC-DC电源变换器的ACC(平均电流模式控制)进行大幅度改进,包括在控制回路中增加一个辅助控制器,除了电流和电压调节器。基于模型的辅助控制器在功率级无源元件、负载和线路电压的大范围变化下,保留了buck衍生转换器的闭环小信号带宽(包括环路增益交叉频率和稳定裕度)。此外,该控制方案具有比传统ACC更好的抗干扰性能(闭环阻抗和听觉敏感性)。从控制理论的角度来看,鲁棒性能是保持稳定的。在不同的LC输出滤波器、线路和负载条件下,包括断续导通模式下,实验测试了一个5 V-5 A、50 kHz降压样机,工作电压范围为30 V至15 V。对转换器的小信号频率响应(环路增益、闭环声敏感度和输出阻抗)进行了测量,显示了所提出的控制方案所取得的改进。为了验证这一概念,本文还给出了变换器在负载阶跃下的经验大信号响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonics filtering and detection of disturbances using wavelets Hybrid position/force control of a mobile manipulator based on cooperative task sharing LMS adaptation of an ARMAX model using the optimum scalar data nonlinearity algorithm Three-phase static series voltage regulator control algorithms for dynamic sag compensation Automatic edge detection of DNA bands in autoradiograph images
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1