Valvular prostheses

Luigi P. Badano, Denisa Muraru
{"title":"Valvular prostheses","authors":"Luigi P. Badano, Denisa Muraru","doi":"10.1093/med/9780198849353.003.0019","DOIUrl":null,"url":null,"abstract":"Prosthetic heart valves may be mechanical or bioprosthetic. Mechanical valves, which are composed primarily of metal or carbon alloys, are classified according to their design as ball-caged, single-tilting-disc, or bileaflet-tilting-disc valves. In ball-cage valves, the occluder is a sphere which is contained by a metal ‘cage’ when the valve is in its open position, and fills the orifice when the valve is in its closed position. In single-tilting-valves, the occluder is a single circular disc which is constrained in its motion by a cage, a central strut, or a slanted slot in the valve ring, therefore it opens at an angle less than 90° to the sewing ring plane. In bileaflet-tilting-disc valves there two occluders, two semicircular discs that open forming three orifices, a central one and two lateral ones. Biological tissue valves prostheses may be heterografts, which are composed of porcine, bovine, or equine tissue (valvular or pericardial), or homografts, which are preserved human aortic valves. Heterografts include stented and stentless bioprostheses. In stented valves, the biological tissue of the valve is mounted on a rigid stent (plastic or metallic) covered with fabric. Conversely stentless bioprostheses use the patient’s native aortic root as the valve stent. The absence of a stent and sewing ring cuff make it possible to implant a larger valve for a given native annulus size, resulting in a larger effective orifice area (EOA).","PeriodicalId":259304,"journal":{"name":"The ESC Textbook of Cardiovascular Imaging","volume":"100 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The ESC Textbook of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/med/9780198849353.003.0019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Prosthetic heart valves may be mechanical or bioprosthetic. Mechanical valves, which are composed primarily of metal or carbon alloys, are classified according to their design as ball-caged, single-tilting-disc, or bileaflet-tilting-disc valves. In ball-cage valves, the occluder is a sphere which is contained by a metal ‘cage’ when the valve is in its open position, and fills the orifice when the valve is in its closed position. In single-tilting-valves, the occluder is a single circular disc which is constrained in its motion by a cage, a central strut, or a slanted slot in the valve ring, therefore it opens at an angle less than 90° to the sewing ring plane. In bileaflet-tilting-disc valves there two occluders, two semicircular discs that open forming three orifices, a central one and two lateral ones. Biological tissue valves prostheses may be heterografts, which are composed of porcine, bovine, or equine tissue (valvular or pericardial), or homografts, which are preserved human aortic valves. Heterografts include stented and stentless bioprostheses. In stented valves, the biological tissue of the valve is mounted on a rigid stent (plastic or metallic) covered with fabric. Conversely stentless bioprostheses use the patient’s native aortic root as the valve stent. The absence of a stent and sewing ring cuff make it possible to implant a larger valve for a given native annulus size, resulting in a larger effective orifice area (EOA).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
瓣膜假体
人工心脏瓣膜可以是机械的或生物的。机械阀主要由金属或碳合金组成,根据其设计分为球笼式、单倾斜阀瓣或双倾斜阀瓣。在球笼阀中,封堵器是一个球体,当阀门处于开启位置时,封堵器被一个金属“笼”所包含,当阀门处于关闭位置时,封堵器充满孔板。在单倾斜阀中,闭塞器是一个单圆盘,它的运动受到阀环中的保持架、中心支柱或斜槽的限制,因此它与缝环平面的夹角小于90°。在双瓣倾斜瓣阀中,有两个闭塞器,两个半圆形的瓣,形成三个孔,一个中心孔和两个外侧孔。生物组织瓣膜假体可以是异种移植物,由猪、牛或马组织(瓣膜或心包)组成,也可以是同种移植物,保存人类主动脉瓣。异种移植物包括有支架和无支架的生物假体。在支架式瓣膜中,瓣膜的生物组织被安装在覆盖有织物的刚性支架(塑料或金属)上。相反,无支架生物假体使用患者的原生主动脉根作为瓣膜支架。由于没有支架和缝合环袖带,因此可以在给定的天然环隙尺寸下植入更大的瓣膜,从而获得更大的有效孔面积(EOA)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The role of echocardiography Tricuspid and pulmonary valve disease Assessment of viability Transcatheter aortic valve implantation Pericardial effusion and cardiac tamponade
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1