A new control method for obtaining reference currents of shunt active power filters in unbalanced and non-sinusoidal conditions

A. Abellán, G. Garcerá, M. Benavent
{"title":"A new control method for obtaining reference currents of shunt active power filters in unbalanced and non-sinusoidal conditions","authors":"A. Abellán, G. Garcerá, M. Benavent","doi":"10.1109/ISIE.1999.798721","DOIUrl":null,"url":null,"abstract":"Shunt active power filters are used to eliminate the current harmonics and to improve the power factor in systems with nonlinear loads. At the present time, different methods exist to control active power filters. Some of them are based on instantaneous reactive power theory and others are based on the synchronous reference frame using Park's transformation. The purpose of this paper is to present a new control method of shunt active power filters in unbalanced systems, both in load currents and in AC supply voltage, with a high contents of harmonics. The method is based on the time-domain analysis carried out by P. Filipski (1980). With this control method, one can make that the set formed by the nonlinear load and the shunt power filter behaves every time like a resistance, UPF (with unity power factor), or that the current absorbed by the set is perfectly sinusoidal, by simply acting on a switch. The system has been simulated for different load and line conditions. Waveforms of the line currents are shown, with their harmonic distortion contents.","PeriodicalId":227402,"journal":{"name":"ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.1999.798721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

Shunt active power filters are used to eliminate the current harmonics and to improve the power factor in systems with nonlinear loads. At the present time, different methods exist to control active power filters. Some of them are based on instantaneous reactive power theory and others are based on the synchronous reference frame using Park's transformation. The purpose of this paper is to present a new control method of shunt active power filters in unbalanced systems, both in load currents and in AC supply voltage, with a high contents of harmonics. The method is based on the time-domain analysis carried out by P. Filipski (1980). With this control method, one can make that the set formed by the nonlinear load and the shunt power filter behaves every time like a resistance, UPF (with unity power factor), or that the current absorbed by the set is perfectly sinusoidal, by simply acting on a switch. The system has been simulated for different load and line conditions. Waveforms of the line currents are shown, with their harmonic distortion contents.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提出了一种在非平衡和非正弦条件下获取并联有源滤波器参考电流的新控制方法
并联型有源电力滤波器用于消除非线性负载系统中的电流谐波,提高系统的功率因数。目前,对有源电力滤波器的控制方法多种多样。其中一些是基于瞬时无功理论,另一些是基于Park变换的同步参照系。本文的目的是提出一种在负载电流和交流供电电压不平衡、谐波含量高的系统中并联有源滤波器的新控制方法。该方法是基于P. Filipski(1980)进行的时域分析。使用这种控制方法,可以使由非线性负载和并联电源滤波器组成的集合每次都表现得像一个电阻,UPF(具有单位功率因数),或者通过简单地作用于开关,该集合吸收的电流是完全正弦的。在不同的负载和线路条件下对系统进行了仿真。给出了线路电流的波形及其谐波畸变量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonics filtering and detection of disturbances using wavelets Hybrid position/force control of a mobile manipulator based on cooperative task sharing LMS adaptation of an ARMAX model using the optimum scalar data nonlinearity algorithm Three-phase static series voltage regulator control algorithms for dynamic sag compensation Automatic edge detection of DNA bands in autoradiograph images
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1