Comparative study of diode laser 940 nm in performing frenectomy in both: Continuous and pulsed modes: An in vivo study

A. Al-Khatib, Asmaa S Al-Azzawi
{"title":"Comparative study of diode laser 940 nm in performing frenectomy in both: Continuous and pulsed modes: An in vivo study","authors":"A. Al-Khatib, Asmaa S Al-Azzawi","doi":"10.4103/0976-2868.158461","DOIUrl":null,"url":null,"abstract":"The Objectives of this Study: The objective of the study was to evaluate the efficiency of diode laser 940 nm in both, continuous and pulsed modes. Then compare the outcomes of frenectomy procedure, and find the best mode that satisfies the patient's and the surgeon's criteria. Materials and Methods: This study was carried out on 14 patients of which 7 were males and 7 were females with age range from 7 to 46 years. Patients underwent diode laser-assisted frenectomy in continuous wave (CW) mode with power ranging from 1.5–3 W and pulsed mode, which was subdivided into comfort pulse 0 (CP0) with 6–10 W peak power; 1.2–2 W average power and CP2with 2–10 W peak power; 1–5 W average power. Anesthesia method and need, the duration of surgery and intraoperative bleeding events were recorded in all cases. In addition, patient preoperative fear, perception and comments were reported. Ratings of the postoperative pain and the functional complications for each patient in a questionnaire survey were reported using the Wong-Baker FACES Pain Rating Scale at operation day throughout the 1st week postoperatively. All patients were examined at 2, 7, and 21 days after the operation in order to assess the surgical wound healing. Results: In the clinical study, seven patients were operated on without infiltration anesthesia (only spray anesthesia) in the pulsed mode while in CW-mode only one patient operated on with spray anesthesia in low power. Intraoperative bleeding events were bloodless to oozing. There was no preoperative fear; patients' perceptions were comfortable with satisfactory comments except in CW cases and some of the CP0 cases. Severe postoperative complications were absent in all subjects. The reported survey results indicated that the patients treated with the laser had normal day activity on operation day, less postoperative pain and fewer functional complications were noticed in the CP2mode. The surgical wound healing was within normal limits in 7–14 days. Carbonization was the main feature of cases treated with CW-mode while it was mostly absent in the pulsed mode. Conclusion: The use of CW-mode of diode laser can be considered no more suitable for performing oral soft tissues surgery. The pulsed mode was found more practical, effective and easy to carry out incisions, cuttings with less intra and postoperative complications considering its advantages in the clinical cases. The CP2pulsed mode laser treatment offers a safe, effective, acceptable, with impressive outcomes particularly for young patients.","PeriodicalId":345720,"journal":{"name":"Journal of Dental Lasers","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Lasers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0976-2868.158461","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The Objectives of this Study: The objective of the study was to evaluate the efficiency of diode laser 940 nm in both, continuous and pulsed modes. Then compare the outcomes of frenectomy procedure, and find the best mode that satisfies the patient's and the surgeon's criteria. Materials and Methods: This study was carried out on 14 patients of which 7 were males and 7 were females with age range from 7 to 46 years. Patients underwent diode laser-assisted frenectomy in continuous wave (CW) mode with power ranging from 1.5–3 W and pulsed mode, which was subdivided into comfort pulse 0 (CP0) with 6–10 W peak power; 1.2–2 W average power and CP2with 2–10 W peak power; 1–5 W average power. Anesthesia method and need, the duration of surgery and intraoperative bleeding events were recorded in all cases. In addition, patient preoperative fear, perception and comments were reported. Ratings of the postoperative pain and the functional complications for each patient in a questionnaire survey were reported using the Wong-Baker FACES Pain Rating Scale at operation day throughout the 1st week postoperatively. All patients were examined at 2, 7, and 21 days after the operation in order to assess the surgical wound healing. Results: In the clinical study, seven patients were operated on without infiltration anesthesia (only spray anesthesia) in the pulsed mode while in CW-mode only one patient operated on with spray anesthesia in low power. Intraoperative bleeding events were bloodless to oozing. There was no preoperative fear; patients' perceptions were comfortable with satisfactory comments except in CW cases and some of the CP0 cases. Severe postoperative complications were absent in all subjects. The reported survey results indicated that the patients treated with the laser had normal day activity on operation day, less postoperative pain and fewer functional complications were noticed in the CP2mode. The surgical wound healing was within normal limits in 7–14 days. Carbonization was the main feature of cases treated with CW-mode while it was mostly absent in the pulsed mode. Conclusion: The use of CW-mode of diode laser can be considered no more suitable for performing oral soft tissues surgery. The pulsed mode was found more practical, effective and easy to carry out incisions, cuttings with less intra and postoperative complications considering its advantages in the clinical cases. The CP2pulsed mode laser treatment offers a safe, effective, acceptable, with impressive outcomes particularly for young patients.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
940 nm二极管激光在连续和脉冲两种模式下行系带切除术的比较研究:一项体内研究
本研究的目的是评估940nm二极管激光器在连续和脉冲两种模式下的效率。然后比较两种系带切除术的效果,找出满足患者和外科医生标准的最佳模式。材料与方法:本研究共纳入14例患者,其中男性7例,女性7例,年龄7 ~ 46岁。采用功率为1.5 ~ 3w的连续波(CW)模式和峰值功率为6 ~ 10w的舒适脉冲(CP0)模式,对患者行二极管激光辅助系带切除术;平均功率1.2-2 W, cp2峰值功率2-10 W;平均功率1 ~ 5w。记录所有病例的麻醉方式、麻醉需要、手术时间及术中出血情况。此外,报告了患者术前的恐惧、感知和评论。术后1周内采用Wong-Baker FACES疼痛评定量表对每位患者的术后疼痛和功能并发症进行问卷调查。所有患者于术后2、7、21天进行检查,以评估手术伤口愈合情况。结果:在临床研究中,7例患者在脉冲模式下进行了无浸润麻醉(仅喷雾麻醉)的手术,而在cw模式下,只有1例患者进行了低功率喷雾麻醉。术中出血从无血到渗血。术前无恐惧;除了CW病例和部分CP0病例外,患者的感觉是满意的。所有受试者均无严重的术后并发症。报告的调查结果表明,激光治疗的患者在手术当天的日常活动正常,术后疼痛较少,cp2模式下功能并发症较少。术后7 ~ 14天伤口愈合正常。碳化是cw模式下的主要特征,而脉冲模式下几乎没有碳化。结论:使用cw模式的二极管激光进行口腔软组织手术是不合适的。考虑到脉冲模式在临床病例中的优势,发现脉冲模式更实用、有效、易于进行切口,切口内及术后并发症少。cp2脉冲模式激光治疗提供了一个安全,有效,可接受的,令人印象深刻的结果,特别是对年轻患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diode laser excision of pyogenic granuloma: A case report Fluid flow analysis of laser-activated irrigation in the simulated root canal Evaluation of the efficacy of Er:YAG laser–activated irrigation in a simulated accessory canal Drug-induced gingival enlargement: A case report Editors message
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1