{"title":"Improved DC-Link Voltage Transient Response and Stability Issues in Energy Router with Fuzzy Logic Control Method","authors":"Mahdieh Najafzadeh, O. Husev, I. Roasto, T. Jalakas","doi":"10.1109/RTUCON51174.2020.9316477","DOIUrl":null,"url":null,"abstract":"This work proposes an intelligent control method for ensuring the Direct Current (DC) link voltage stability and for improving the DC-link voltage transient response in a residential Energy Router (ER). This ER is an interface among the main grid, local AC or DC loads and sources. When connecting different loads to the DC-link, the classic Proportional Integrator Derivative (PID) controller has been unable to provide a stable DC-link voltage. In this study, the PID controller will be compared with the proposed fuzzy logic controller in different DC load levels. The results prove the enhanced functionality of the proposed control method.","PeriodicalId":332414,"journal":{"name":"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON51174.2020.9316477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This work proposes an intelligent control method for ensuring the Direct Current (DC) link voltage stability and for improving the DC-link voltage transient response in a residential Energy Router (ER). This ER is an interface among the main grid, local AC or DC loads and sources. When connecting different loads to the DC-link, the classic Proportional Integrator Derivative (PID) controller has been unable to provide a stable DC-link voltage. In this study, the PID controller will be compared with the proposed fuzzy logic controller in different DC load levels. The results prove the enhanced functionality of the proposed control method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于模糊逻辑控制的能量路由器直流电压暂态响应及稳定性研究
本文提出了一种智能控制方法,以保证直流链路电压的稳定性,并改善住宅能源路由器直流链路电压的瞬态响应。该ER是主电网、本地交流或直流负载和电源之间的接口。当将不同负载连接到直流链路时,传统的比例积分导数(PID)控制器已经无法提供稳定的直流链路电压。在本研究中,将PID控制器与所提出的模糊控制器在不同的直流负载水平下进行比较。结果证明了所提控制方法的增强功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring the impact of demand response services on electricity prices in Latvian electricity market Case Studies for Optimal Cable Line Placement and Sheath Grounding to Increase its Operational Characteristics Reduction of Electromagnetic Emissions Generated by Inductive Resonant WPT Systems Using Multi-Switching-Frequency-Based Method Economic Assessment Of The Efficiency Of The Application Of Energy Storage System To Compensate The Load Rise And Shedding Of Gas Piston Installation Control Algorithms Based on Load Angle and Phase Current Difference for Traction Switched Reluctance Motor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1