Design and Implementation of Remote Medicine Monitoring System Based on Internet of Things

Lei Wang, Kunqin Li, Xianxiang Chen
{"title":"Design and Implementation of Remote Medicine Monitoring System Based on Internet of Things","authors":"Lei Wang, Kunqin Li, Xianxiang Chen","doi":"10.1145/3424978.3425128","DOIUrl":null,"url":null,"abstract":"Intravenous drip, commonly known as infusion, is one of the most commonly used treatment and rescue measures in clinical practice. In the process of infusion, newborns, children, adults and the elderly have different requirements for infusion speed. Patients with poor metabolism of cardiopulmonary function and renal function need special attention, because infusion speed is not only related to the patient's heart load capacity, but also affects the efficacy of drugs, and even some patients will have drug reactions due to too fast infusion dripping speed. Besides, some problems such as untimely dosing, manual control of dripping speed and inconvenient call for medical staff exist in the process of infusion. Aiming at the above problems, in this paper, a remote medical monitoring system based on STC89C52 is proposed and designed. In the ward, sensors are used to detect the liquid level and dripping speed of liquid during infusion. Through ZigBee CC2530 wireless transmission, the infusion information is sent to the nurse end to realize remote monitoring. If there is too little medicine left or the infusion dripping speed is too fast during infusion, the alarm occurred in time, and meanwhile the infusion dripping speed can be controlled. After tested, the system runs stably, and the required functions such as real-time liquid level monitoring, real-time dripping speed monitoring, intelligent dripping speed adjustment and automatic alarm can be realized, which indicates that by using this system, the problems of the traditional infusion system can be solved, which has a strong practical value.","PeriodicalId":178822,"journal":{"name":"Proceedings of the 4th International Conference on Computer Science and Application Engineering","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 4th International Conference on Computer Science and Application Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3424978.3425128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Intravenous drip, commonly known as infusion, is one of the most commonly used treatment and rescue measures in clinical practice. In the process of infusion, newborns, children, adults and the elderly have different requirements for infusion speed. Patients with poor metabolism of cardiopulmonary function and renal function need special attention, because infusion speed is not only related to the patient's heart load capacity, but also affects the efficacy of drugs, and even some patients will have drug reactions due to too fast infusion dripping speed. Besides, some problems such as untimely dosing, manual control of dripping speed and inconvenient call for medical staff exist in the process of infusion. Aiming at the above problems, in this paper, a remote medical monitoring system based on STC89C52 is proposed and designed. In the ward, sensors are used to detect the liquid level and dripping speed of liquid during infusion. Through ZigBee CC2530 wireless transmission, the infusion information is sent to the nurse end to realize remote monitoring. If there is too little medicine left or the infusion dripping speed is too fast during infusion, the alarm occurred in time, and meanwhile the infusion dripping speed can be controlled. After tested, the system runs stably, and the required functions such as real-time liquid level monitoring, real-time dripping speed monitoring, intelligent dripping speed adjustment and automatic alarm can be realized, which indicates that by using this system, the problems of the traditional infusion system can be solved, which has a strong practical value.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于物联网的远程医疗监控系统的设计与实现
静脉滴注,俗称输注,是临床上最常用的治疗和抢救措施之一。在输液过程中,新生儿、儿童、成人和老年人对输液速度有不同的要求。心肺功能和肾功能代谢较差的患者需要特别注意,因为输液速度不仅关系到患者的心脏负荷能力,还会影响药物的疗效,甚至有些患者会因输液滴速过快而发生药物反应。此外,在输液过程中还存在给药不及时、人工控制滴速、医护人员呼叫不便等问题。针对以上问题,本文提出并设计了一种基于STC89C52的远程医疗监控系统。在病房中,传感器用于检测输液过程中液体的液位和滴速。通过ZigBee CC2530无线传输,将输液信息发送到护理端,实现远程监控。如果在输液过程中剩余药量过少或滴注速度过快,及时报警,同时控制滴注速度。经测试,系统运行稳定,能够实现实时液位监测、实时滴速监测、智能滴速调节、自动报警等所需功能,说明使用该系统可以解决传统输液系统存在的问题,具有较强的实用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study on Improved Algorithm of RSSI Correction and Location in Mine-well Based on Bluetooth Positioning Information Distributed Predefined-time Consensus Tracking Protocol for Multi-agent Systems Evaluation Method Study of Blog's Subject Influence and User's Subject Influence Performance Evaluation of Full Turnover-based Policy in the Flow-rack AS/RS A Hybrid Encoding Based Particle Swarm Optimizer for Feature Selection and Classification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1