Development and test of TAB bonded micro-cables for silicon detectors in a Compton prostate probe

C. Lacasta, J. Bernabeu, V. Borshchov, D. Burdette, E. Chesi, N. Clinthorne, Y. Dewaraja, K. Honscheid, H. Kagan, A. Listratenko, G. Llosá, M. Mikuž, P. Modesto, M. Protsenko, W. Rogers, V. Starkov, A. Studen, P. Weilhammer, L. Zhang, G. Zinovjev, D. Žontar
{"title":"Development and test of TAB bonded micro-cables for silicon detectors in a Compton prostate probe","authors":"C. Lacasta, J. Bernabeu, V. Borshchov, D. Burdette, E. Chesi, N. Clinthorne, Y. Dewaraja, K. Honscheid, H. Kagan, A. Listratenko, G. Llosá, M. Mikuž, P. Modesto, M. Protsenko, W. Rogers, V. Starkov, A. Studen, P. Weilhammer, L. Zhang, G. Zinovjev, D. Žontar","doi":"10.1109/NSSMIC.2005.1596969","DOIUrl":null,"url":null,"abstract":"This contribution describes the work made towards packaging optimization in the frame of the development of an endorectal probe for imaging the prostate. This application is based on the concept of electronic collimation for single gamma detection taking advantage of the Compton scattering of the photons in a stack of 1 mm thick silicon pad detectors and their later absorption in an external detector. This concept allows to remove the mechanical collimators used in the usual gamma cameras and, therefore, provides the possibility of improving both sensitivity and resolution. Packaging of the silicon sensors and their associated electronics is of paramount importance in this application. To address this important aspect of the device we have explored the tape automated bonding (TAB) technique for the connection of the silicon sensors to the readout electronics and for routing the signals to the outside. TAB offers an elegant solution not only for a flexible and compact interconnection between the readout ASICs and the sensors but also for ASIC selection and testing prior to the assembly of the detector and their associated readout electronics","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"146 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This contribution describes the work made towards packaging optimization in the frame of the development of an endorectal probe for imaging the prostate. This application is based on the concept of electronic collimation for single gamma detection taking advantage of the Compton scattering of the photons in a stack of 1 mm thick silicon pad detectors and their later absorption in an external detector. This concept allows to remove the mechanical collimators used in the usual gamma cameras and, therefore, provides the possibility of improving both sensitivity and resolution. Packaging of the silicon sensors and their associated electronics is of paramount importance in this application. To address this important aspect of the device we have explored the tape automated bonding (TAB) technique for the connection of the silicon sensors to the readout electronics and for routing the signals to the outside. TAB offers an elegant solution not only for a flexible and compact interconnection between the readout ASICs and the sensors but also for ASIC selection and testing prior to the assembly of the detector and their associated readout electronics
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于康普顿前列腺探针硅探测器的TAB键合微电缆的开发和测试
这一贡献描述了工作朝着包装优化的框架内的直肠内探头成像前列腺的发展。该应用基于单伽马探测的电子准直概念,利用光子在1毫米厚的硅衬垫探测器堆栈中的康普顿散射及其随后在外部探测器中的吸收。这个概念允许移除通常伽玛相机中使用的机械准直器,因此,提供了提高灵敏度和分辨率的可能性。硅传感器及其相关电子器件的封装在此应用中至关重要。为了解决该设备的这一重要方面,我们探索了用于将硅传感器连接到读出电子器件并将信号路由到外部的磁带自动键合(TAB)技术。TAB提供了一个优雅的解决方案,不仅用于读出ASIC和传感器之间灵活紧凑的互连,而且还用于在检测器及其相关读出电子设备组装之前进行ASIC选择和测试
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Monte Carlo optimization of an industrial tomography system A scalable system for microcalcification cluster automated detection in a distributed mammographic database The BaBar muon system upgrade Fast, long-wavelength scintillators and waveshifters New effects observed in the BaBar silicon vertex tracker: interpretation and estimate of their impact on the future performance of the detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1