{"title":"Noncontact Doppler Radar-based Heart Rate Detection on the SVD and ANC","authors":"Qiuxia Shi, Bin Hu, Fuze Tian, Qinglin Zhao","doi":"10.1109/BIBM55620.2022.9994893","DOIUrl":null,"url":null,"abstract":"In the Doppler biological radar-based applications of noncontact measurement of vital signs, effectively extracting heartbeat information from weak thoracic mechanical motion is an important problem to be solved. This study is aimed at extracting heartbeat signal via the technology combined with Short Time Fourier Transform (STFT), Singular Value Decomposition (SVD) and Adaptive Noise Canceller (ANC) from radar recording. The simulated data and the data collected by Doppler radar biosensor realized in laboratory are employed to validate the proposed method. The results show that the proposed method has the ability of detection for the heart rate and heart rate variability indexes in rest state, it has certain advantages in time-consuming and detection accuracy. Therefore, the current method provides another way to process vital sign signals recorded by Doppler radar.","PeriodicalId":210337,"journal":{"name":"2022 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBM55620.2022.9994893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In the Doppler biological radar-based applications of noncontact measurement of vital signs, effectively extracting heartbeat information from weak thoracic mechanical motion is an important problem to be solved. This study is aimed at extracting heartbeat signal via the technology combined with Short Time Fourier Transform (STFT), Singular Value Decomposition (SVD) and Adaptive Noise Canceller (ANC) from radar recording. The simulated data and the data collected by Doppler radar biosensor realized in laboratory are employed to validate the proposed method. The results show that the proposed method has the ability of detection for the heart rate and heart rate variability indexes in rest state, it has certain advantages in time-consuming and detection accuracy. Therefore, the current method provides another way to process vital sign signals recorded by Doppler radar.