Comparing reactance one-port and notch filters for voltage and current harmonic reduction in nonlinear distribution systems

E. El-Saadany, M. Salama, A. Chikhani
{"title":"Comparing reactance one-port and notch filters for voltage and current harmonic reduction in nonlinear distribution systems","authors":"E. El-Saadany, M. Salama, A. Chikhani","doi":"10.1109/CCECE.1998.685632","DOIUrl":null,"url":null,"abstract":"Harmonic distortion in distribution systems has escalated in recent years due to the widespread use of different nonlinear and electronically switched loads. This paper deals with decreasing the harmonics in three-phase four-wire distribution systems loaded with different nonlinear loads. Two approaches have been implemented in order to achieve the desired goal. The first is the utilization of a reactance one-port compensator and the second is the use of notch filters tuned at the prospective harmonics to be eliminated. A concrete example is given to demonstrate the differences between both methods. The harmonic analysis is carried out in the time-domain utilizing the EMTP package in order to accurately represent both system nonlinearity and voltage dependency.","PeriodicalId":177613,"journal":{"name":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","volume":"429 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.1998.685632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Harmonic distortion in distribution systems has escalated in recent years due to the widespread use of different nonlinear and electronically switched loads. This paper deals with decreasing the harmonics in three-phase four-wire distribution systems loaded with different nonlinear loads. Two approaches have been implemented in order to achieve the desired goal. The first is the utilization of a reactance one-port compensator and the second is the use of notch filters tuned at the prospective harmonics to be eliminated. A concrete example is given to demonstrate the differences between both methods. The harmonic analysis is carried out in the time-domain utilizing the EMTP package in order to accurately represent both system nonlinearity and voltage dependency.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较电抗单端滤波器和陷波滤波器在非线性配电系统中抑制电压和电流谐波的作用
近年来,由于各种非线性和电子开关负载的广泛使用,配电系统中的谐波失真日益严重。本文研究了三相四线制配电系统中不同非线性负荷的谐波降低问题。为了达到预期的目标,已经实施了两种方法。第一个是利用一个电抗单端口补偿器,第二个是使用陷波滤波器在预期的谐波被消除。给出了一个具体的例子来说明这两种方法的区别。利用EMTP包在时域进行谐波分析,以便准确地表示系统非线性和电压依赖性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The use of ISDN signaling for real-time applications at homes and small businesses Multifractal analysis of DNA Multimedia courseware delivery over the Internet The VideoWriter: towards active paper for a natural user interface A performance based analysis of a robust flux controller for an induction motor drive
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1