Case study: H-piles driven into shale rock for compression and uplift resistance

I. Oweis, S. Anthony
{"title":"Case study: H-piles driven into shale rock for compression and uplift resistance","authors":"I. Oweis, S. Anthony","doi":"10.1080/19375247.2018.1521608","DOIUrl":null,"url":null,"abstract":"The case study describes dynamic PDA tests conducted on four driven piles in fractured shale where rock penetration ranged from 0.98 to 2.3 m. The pile (HP360x174) was driven with a diesel hammer at a maximum rated energy of 100.47 kN-m. A steel shoe flush with the pile outside dimension was used. The piles reached practical refusal at 50 blows per 25 mm. The CAPWAP and estimated rock penetration established a unit tip bearing resistance of 24.9 MPa and a unit side resistance of 707 kPa. A plugged section was assumed. The unit side resistance is consistent with the recommendation in the AGMU10.2 manual by the Illinois DOT, but the tip resistance observed is almost four times what is recommended in the manual.","PeriodicalId":272645,"journal":{"name":"DFI Journal - The Journal of the Deep Foundations Institute","volume":"125 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DFI Journal - The Journal of the Deep Foundations Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19375247.2018.1521608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The case study describes dynamic PDA tests conducted on four driven piles in fractured shale where rock penetration ranged from 0.98 to 2.3 m. The pile (HP360x174) was driven with a diesel hammer at a maximum rated energy of 100.47 kN-m. A steel shoe flush with the pile outside dimension was used. The piles reached practical refusal at 50 blows per 25 mm. The CAPWAP and estimated rock penetration established a unit tip bearing resistance of 24.9 MPa and a unit side resistance of 707 kPa. A plugged section was assumed. The unit side resistance is consistent with the recommendation in the AGMU10.2 manual by the Illinois DOT, but the tip resistance observed is almost four times what is recommended in the manual.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
案例研究:h型桩打入页岩进行抗压抗拔
该案例研究描述了在裂缝性页岩中对4个打入桩进行的动态PDA测试,岩石穿深范围为0.98 ~ 2.3 m。桩(HP360x174)用柴油锤打桩,最大额定能量为100.47 kN-m。采用与桩外径齐平的钢靴。桩在每25毫米打50下时达到实际拒绝。根据CAPWAP和岩石侵彻量估算,单位尖端阻力为24.9 MPa,单位侧阻力为707 kPa。假设有一个堵塞的部分。单位侧电阻与伊利诺伊州DOT在AGMU10.2手册中的建议一致,但观察到的尖端电阻几乎是手册中建议的四倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Editorial Note – Issue 3 (2018) Measured end resistance of CFA and drilled displacement piles in San Francisco Area alluvial clay DFI Journal Underwriters A sensitivity analysis on the parameters affecting large diameter helical pile installation torque, depth and installation power for offshore applications The deep soil mixing for the Galataport project in Istanbul, Turkey
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1