{"title":"Modelling of low-voltage grids with high PV share and Q(U)-control","authors":"D. Schultis, Stefan Petrusic, A. Ilo","doi":"10.1049/oap-cired.2021.0101","DOIUrl":null,"url":null,"abstract":": Climate challenges foster the integration of rooftop photovoltaic (PV) appliances. The associated inverters are often equipped with local Q ( U ) control to mitigate the voltage limit violations in low-voltage feeders. Their presence strongly modifies the behaviour of low-voltage grids. The common lumped model of the latter, which is used for load flow analysis in medium-voltage level, cannot describe their new behaviour. In this study, two lumped models of low-voltage grids are analysed and compared: the common or simplified one that does not consider the effect of the grid itself and the inverters ’ different working points in the Q ( U ) characteristic; and the exact one. Power flow simulations are performed in low-and medium-voltage test grids for maximal PV production. Results reveal high errors of the simplified lumped model that lead to incorrect power flow in medium-voltage grid.","PeriodicalId":405107,"journal":{"name":"CIRED - Open Access Proceedings Journal","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CIRED - Open Access Proceedings Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/oap-cired.2021.0101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
: Climate challenges foster the integration of rooftop photovoltaic (PV) appliances. The associated inverters are often equipped with local Q ( U ) control to mitigate the voltage limit violations in low-voltage feeders. Their presence strongly modifies the behaviour of low-voltage grids. The common lumped model of the latter, which is used for load flow analysis in medium-voltage level, cannot describe their new behaviour. In this study, two lumped models of low-voltage grids are analysed and compared: the common or simplified one that does not consider the effect of the grid itself and the inverters ’ different working points in the Q ( U ) characteristic; and the exact one. Power flow simulations are performed in low-and medium-voltage test grids for maximal PV production. Results reveal high errors of the simplified lumped model that lead to incorrect power flow in medium-voltage grid.