{"title":"A short-circuit current calculation method for low-voltage DC microgrid","authors":"Xiaoli Lai, Fei Liu, Kai Deng, Qi Gao, X. Zha","doi":"10.1109/PEAC.2014.7037883","DOIUrl":null,"url":null,"abstract":"Short-circuiting in dc lines affects the security and reliability of dc microgrid greatly. A short-circuit current calculation method for low-voltage dc microgrid is proposed in this paper. To solve the calculation of short-circuit current, a line model of bipolar which includes π type equivalent circuits, solid-state bidirectional switches with snubber circuits and freewheeling branches is adopted. The line current under different short-circuit fault types in dc bus is discussed and the circuit working mechanisms before and after solid-state switches action are analyzed, and then the analytic expressions of the line fault current are derived. Besides, the freewheeling loop of the short-circuit current is also analyzed after the removal of fault. The correctness of the analytic expressions is verified by MATLAB/Simulink simulations.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
Short-circuiting in dc lines affects the security and reliability of dc microgrid greatly. A short-circuit current calculation method for low-voltage dc microgrid is proposed in this paper. To solve the calculation of short-circuit current, a line model of bipolar which includes π type equivalent circuits, solid-state bidirectional switches with snubber circuits and freewheeling branches is adopted. The line current under different short-circuit fault types in dc bus is discussed and the circuit working mechanisms before and after solid-state switches action are analyzed, and then the analytic expressions of the line fault current are derived. Besides, the freewheeling loop of the short-circuit current is also analyzed after the removal of fault. The correctness of the analytic expressions is verified by MATLAB/Simulink simulations.