{"title":"Air Conditioning Consumption Optimization Based on CO2 Concentration Level","authors":"Mahsa Khorram, Modar Zheiry, P. Faria, Z. Vale","doi":"10.1109/ISAP48318.2019.9065967","DOIUrl":null,"url":null,"abstract":"Nowadays, energy consumption increasing is a big concern for many countries around the world. Disadvantages and consequences of fossil fuels for the environment caused a lot of efforts to invest in renewable energy resources and programs to optimize energy consumption. All types of buildings are the major consumers of electric power. Therefore, buildings can be considered as good options for implementing optimization algorithms, assuming that they are equipped to required infrastructures. Air conditioners are flexible loads that can be directly controlled by optimization programs. This paper presents a particle swarm optimization algorithm to minimize the power consumption of the air conditioners based on the carbon dioxide concentration level. The algorithm considers the thermal comfort of users with defining restrictions. The case study of the paper proposes two scenarios with real monitored data of a building. The result of the paper shows the obtained results of the algorithm and makes the comparison of two scenarios.","PeriodicalId":316020,"journal":{"name":"2019 20th International Conference on Intelligent System Application to Power Systems (ISAP)","volume":"58 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 20th International Conference on Intelligent System Application to Power Systems (ISAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP48318.2019.9065967","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Nowadays, energy consumption increasing is a big concern for many countries around the world. Disadvantages and consequences of fossil fuels for the environment caused a lot of efforts to invest in renewable energy resources and programs to optimize energy consumption. All types of buildings are the major consumers of electric power. Therefore, buildings can be considered as good options for implementing optimization algorithms, assuming that they are equipped to required infrastructures. Air conditioners are flexible loads that can be directly controlled by optimization programs. This paper presents a particle swarm optimization algorithm to minimize the power consumption of the air conditioners based on the carbon dioxide concentration level. The algorithm considers the thermal comfort of users with defining restrictions. The case study of the paper proposes two scenarios with real monitored data of a building. The result of the paper shows the obtained results of the algorithm and makes the comparison of two scenarios.