Textile electrodes for bioimpedance measuring

J. T. Meding, Khorolsuren Tuvshinbayar, C. Döpke, Ferdinand Tamoué
{"title":"Textile electrodes for bioimpedance measuring","authors":"J. T. Meding, Khorolsuren Tuvshinbayar, C. Döpke, Ferdinand Tamoué","doi":"10.25367/cdatp.2021.2.p49-60","DOIUrl":null,"url":null,"abstract":"This article deals with the development and comparison of eight different electrodes made out of a cotton fabric substrate, a silver coated yarn and partly conductive finishes, i.e. a PEDOT:PSS Orgacon ICP 1050 dip-coating and a Powersil coating. The purpose is the application especially in the medical field of angiopathy like for bioimpedance measurements during compression therapies. To be able to compare the suitability of the electrodes, various tests have been performed of the coating abrasion resistance, the stability of electrical resistance values, as well as resistance and bioimpedance measurements. Significant differences between the electrodes regarding their resilience and resistance that are visualized in a value-added analysis were found, with one hand-embroidered, one machine-sewn and one commercial electrode showing optimum properties.","PeriodicalId":106695,"journal":{"name":"Communications in Development and Assembling of Textile Products","volume":"203 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Communications in Development and Assembling of Textile Products","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25367/cdatp.2021.2.p49-60","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This article deals with the development and comparison of eight different electrodes made out of a cotton fabric substrate, a silver coated yarn and partly conductive finishes, i.e. a PEDOT:PSS Orgacon ICP 1050 dip-coating and a Powersil coating. The purpose is the application especially in the medical field of angiopathy like for bioimpedance measurements during compression therapies. To be able to compare the suitability of the electrodes, various tests have been performed of the coating abrasion resistance, the stability of electrical resistance values, as well as resistance and bioimpedance measurements. Significant differences between the electrodes regarding their resilience and resistance that are visualized in a value-added analysis were found, with one hand-embroidered, one machine-sewn and one commercial electrode showing optimum properties.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生物阻抗测量用纺织电极
本文讨论了由棉织物基材、镀银纱和部分导电饰面(即PEDOT:PSS Orgacon ICP 1050浸渍涂层和Powersil涂层)制成的八种不同电极的发展和比较。目的是应用特别是在血管疾病的医学领域,如压迫治疗期间的生物阻抗测量。为了比较电极的适用性,对涂层的耐磨性、电阻值的稳定性以及电阻和生物阻抗测量进行了各种测试。在增值分析中发现,电极之间在弹性和电阻方面存在显着差异,其中一个手工刺绣,一个机器缝制和一个商业电极显示出最佳性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The use of phosphorescence micromaterials for commercial textile products R principles for circular economy in the textile industry – a mini-review Exploring the attractiveness of combinations of natural colors and contemporary shapes in fashion design Fashion meets medicine on the catwalk Design tool for automated crocheting of fabrics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1