Analisis Indeks Paparan Radiografi Digital Pada Pemeriksaan Radiologi Thoraks Postero Anterior Sebagai Upaya Peningkatan Proteksi Radiasi Pasien

Aris Samsul
{"title":"Analisis Indeks Paparan Radiografi Digital Pada Pemeriksaan Radiologi Thoraks Postero Anterior Sebagai Upaya Peningkatan Proteksi Radiasi Pasien","authors":"Aris Samsul","doi":"10.31983/jimed.v8i1.7765","DOIUrl":null,"url":null,"abstract":"ABSTRACT Backgound:  Digital radiography is an easy method of radiological examination, so many radiology technicians often use high exposure factors because they are considered to speed up when processing images, this can increase the risk of excessive radiation doses in patients, currently the exposure index (IE) is feedback to radiology technicians for optimal images and low doses for patients. Objective: evaluating Fujifilm (S-Value) exposure index and entrance surface dose (ESD) thorax posterior-anterior as an effort to increase patient radiation protection using the ALARA principle, Method: Data taken from samples with parameters 64 kVp 16 mAs to 94 kVp 2 mAs, ESD is measured using the thermoluminescent dosimeter (TLD) chip and exposure index (S-Value) from Fujifilm's direct radiography device. Result: The relationship between S-Value and ESD has an exponential trend graph. The rise of S-Value will be followed by the ESD sequence. With the BAPETEN reference value of surface radiation dose 0.40 mGy, the minimum S-value must be achieved so that the patient's ESD does not exceed S-532 at ESD 0.39. Conclusion: The results of this study indicate that Fujifilm's S-Value allows it to be used as an evaluation of the ESD values received by patients as an effort to increase patient radiation protection. Keywords:  Exposure index (S-Value), ESD, chest radiography, radiation protection","PeriodicalId":205622,"journal":{"name":"Jurnal Imejing Diagnostik (JImeD)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Imejing Diagnostik (JImeD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jimed.v8i1.7765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Backgound:  Digital radiography is an easy method of radiological examination, so many radiology technicians often use high exposure factors because they are considered to speed up when processing images, this can increase the risk of excessive radiation doses in patients, currently the exposure index (IE) is feedback to radiology technicians for optimal images and low doses for patients. Objective: evaluating Fujifilm (S-Value) exposure index and entrance surface dose (ESD) thorax posterior-anterior as an effort to increase patient radiation protection using the ALARA principle, Method: Data taken from samples with parameters 64 kVp 16 mAs to 94 kVp 2 mAs, ESD is measured using the thermoluminescent dosimeter (TLD) chip and exposure index (S-Value) from Fujifilm's direct radiography device. Result: The relationship between S-Value and ESD has an exponential trend graph. The rise of S-Value will be followed by the ESD sequence. With the BAPETEN reference value of surface radiation dose 0.40 mGy, the minimum S-value must be achieved so that the patient's ESD does not exceed S-532 at ESD 0.39. Conclusion: The results of this study indicate that Fujifilm's S-Value allows it to be used as an evaluation of the ESD values received by patients as an effort to increase patient radiation protection. Keywords:  Exposure index (S-Value), ESD, chest radiography, radiation protection
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前胸腔Postero后放射检查的数字放射线暴露索引分析,以增加患者的辐射保护
背景:数字放射照相是一种简便的放射学检查方法,因此许多放射技术人员在处理图像时往往考虑到加快速度而采用高暴露系数,这会增加患者辐射剂量过大的风险,目前的暴露指数(IE)是向放射技术人员反馈的,以获得最佳图像和患者低剂量。目的:利用ALARA原理评价富士胶片(S-Value)暴露指数和入口表面剂量(ESD)胸后前位提高患者辐射防护的效果。方法:数据采集参数为64 kVp 16 mAs ~ 94 kVp 2 mAs的样品,ESD采用热致发光剂量计(TLD)芯片测量,暴露指数(S-Value)采用富士胶片直接x线摄影装置测量。结果:s值与ESD呈指数关系。随着s值的上升,ESD序列随之产生。BAPETEN的表面辐射剂量参考值为0.40 mGy,在ESD 0.39时,必须达到最小s值,使患者的ESD不超过S-532。结论:本研究结果表明,富士胶片的s值可用于评估患者接受的ESD值,以增加患者的辐射防护。关键词:暴露指数(s值),ESD,胸片,辐射防护
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluasi Pemeriksaan MRI Brain dengan Klinis Vertigo di Rumah Sakit Otak dr. Drs. M. Hatta Bukittinggi Implementasi Pemanfaatan Sumber Radiasi Pengion pada Ruang CT Scan ditinjau berdasarkan Peraturan BAPETEN No. 4 tahun 2020 di Instalasi Radiologi Rumah Sakit type B di Wilayah Kabupaten Sumedang Nilai Entrance Skin Dose Tiroid antara menggunakan Thyroid Shield dan tanpa Thyroid Shield pada Pemeriksaan CT Scan Kepala Analisis Informasi Anatomi Pemeriksaan MRI Ankle Joint pada Penggunaan Foot Ankle Coil dan Flex Coil Proton Density Fat Saturation Irisan Sagital Evaluasi Kualitas Radiograf Periapikal Teknik Bisektris : Kesalahan Penempatan Sudut Penyinaran dan Film
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1