{"title":"A comparative analysis of stability for battery energy storage system operating with diesel generator in a stand-alone microgrid","authors":"Jongmin Jo, H. Cha","doi":"10.1109/IESES.2018.8349891","DOIUrl":null,"url":null,"abstract":"In this paper, stability of current control of battery energy storage system (BESS) connected with a diesel generator for a stand-alone microgrid are analyzed in four cases. The stand-alone microgrid system consists of 50kW BESS, 50kW diesel generator and controllable loads, where BESS is composed of 115kWh battery bank and 50kW DC-AC inverter. The four cases are 1) BESS with a stiff grid 2) BESS with the diesel generator 3) BESS with passive damping + diesel generator 4) BESS with active damping + diesel generator, and their stabilities are analyzed in the frequency domain and discrete time domain. Demonstration site for the stand-alone microgrid is constructed and comparative analysis for the four cases are verified through simulation and experiments, where experimental results show a good agreement with the analysis.","PeriodicalId":146951,"journal":{"name":"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)","volume":"200 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IESES.2018.8349891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In this paper, stability of current control of battery energy storage system (BESS) connected with a diesel generator for a stand-alone microgrid are analyzed in four cases. The stand-alone microgrid system consists of 50kW BESS, 50kW diesel generator and controllable loads, where BESS is composed of 115kWh battery bank and 50kW DC-AC inverter. The four cases are 1) BESS with a stiff grid 2) BESS with the diesel generator 3) BESS with passive damping + diesel generator 4) BESS with active damping + diesel generator, and their stabilities are analyzed in the frequency domain and discrete time domain. Demonstration site for the stand-alone microgrid is constructed and comparative analysis for the four cases are verified through simulation and experiments, where experimental results show a good agreement with the analysis.