{"title":"Variable Frequency Transformers for Increased Wind Penetration","authors":"T. Geetha, V. Jayashankar","doi":"10.1109/ICPST.2008.4745225","DOIUrl":null,"url":null,"abstract":"The voltage impact of wind farms on weak grids is studied using a generic test system. The size of the wind farm is taken as 20% of the grid short circuit MVA to characterize weak grids. The voltage at the point of interconnection (POI) of the wind farm to the grid is analyzed for different values of grid X/R ratios. It is shown that reduction of real power injection at POI brings the voltage at POI within permissible values for the entire range of X/R ratios. A pumped storage unit or a variable frequency transformer as an asynchronous inter connector is suggested to realize this. Complete modeling and simulation of the proposed network topologies are given. The results are discussed with reference to the Indian power system.","PeriodicalId":107016,"journal":{"name":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2008.4745225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The voltage impact of wind farms on weak grids is studied using a generic test system. The size of the wind farm is taken as 20% of the grid short circuit MVA to characterize weak grids. The voltage at the point of interconnection (POI) of the wind farm to the grid is analyzed for different values of grid X/R ratios. It is shown that reduction of real power injection at POI brings the voltage at POI within permissible values for the entire range of X/R ratios. A pumped storage unit or a variable frequency transformer as an asynchronous inter connector is suggested to realize this. Complete modeling and simulation of the proposed network topologies are given. The results are discussed with reference to the Indian power system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
增加风穿透的变频变压器
利用通用测试系统研究了风电场对弱电网的电压影响。以风电场的规模为电网短路MVA的20%来表征弱电网。在不同的电网X/R比值下,分析了风电场与电网的连接点电压(POI)。结果表明,降低POI处的实际功率注入使POI处的电压在整个X/R比范围内的允许值之内。建议采用抽水蓄能装置或变频变压器作为异步互联装置。给出了所提出的网络拓扑的完整建模和仿真。并以印度电力系统为例进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Formulas for Calculating Physical Grounding Resistance of Grounding Wire - Electric Pole System of High Voltage Transmission Lines Torque Ripple Minimization in Direct Torque Control based IM Drive Part-I: Single-rate Control Strategy Power Systems Voltage Stability Using Artificial Neural Network Ranking of Prospective New Generation Location for a Power Network in a Deregulated System Design of Genetic Algorithm Based Fuzzy Logic Power System Stabilizers in Multimachine Power System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1