Rupture detection for exenteration of tissues using two-DOF haptic surgical forceps robot

Yusuke Kasahara, K. Kitamura, K. Ohnishi, Y. Morikawa, N. Shimojima
{"title":"Rupture detection for exenteration of tissues using two-DOF haptic surgical forceps robot","authors":"Yusuke Kasahara, K. Kitamura, K. Ohnishi, Y. Morikawa, N. Shimojima","doi":"10.1109/AMC.2010.5464119","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel method which detects a rupture of organs based on environmental impedance estimation. The proposed method detects the rupture of the organs which is conducive to serious medical accident. The environmental impedance is estimated from position and force responses of a surgery robot by using recursive least-squares algorithm. The rupture behavior is analyzed, and thresholds are settled with respect to each organ to detect the rupture. In the experiment, a two-DOF haptic surgical forceps robot which implements the bilateral control based on robust acceleration control is used. The experimental results show the effectiveness of the proposed method.","PeriodicalId":406900,"journal":{"name":"2010 11th IEEE International Workshop on Advanced Motion Control (AMC)","volume":"118 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 11th IEEE International Workshop on Advanced Motion Control (AMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMC.2010.5464119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

This paper proposes a novel method which detects a rupture of organs based on environmental impedance estimation. The proposed method detects the rupture of the organs which is conducive to serious medical accident. The environmental impedance is estimated from position and force responses of a surgery robot by using recursive least-squares algorithm. The rupture behavior is analyzed, and thresholds are settled with respect to each organ to detect the rupture. In the experiment, a two-DOF haptic surgical forceps robot which implements the bilateral control based on robust acceleration control is used. The experimental results show the effectiveness of the proposed method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于二自由度触觉手术钳机器人的组织穿刺破裂检测
提出了一种基于环境阻抗估计的器官破裂检测方法。该方法对器官破裂进行检测,有利于重大医疗事故的发生。利用递推最小二乘算法从手术机器人的位置和力响应中估计环境阻抗。分析了各器官的破裂行为,确定了各器官的破裂阈值。实验采用了一种基于鲁棒加速度控制的双自由度触觉手术钳机器人。实验结果表明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Incremental closed-form solution to globally consistent 2D range scan mapping with two-step pose estimation A proposal of feature extraction for impression analysis Advanced contouring error compensation in high performance motion control systems Smooth touch and force control to unknown environment without force sensor for industrial robot A simplified structure for robustness enhancement of time-delay systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1