Noise Level and its Sources in Neonatal Intensive Care Units of Selected Public Hospitals in Kigali City

Ruth Dusabe, A. Muhayimana, Patrice Mujawimana, P. Meharry
{"title":"Noise Level and its Sources in Neonatal Intensive Care Units of Selected Public Hospitals in Kigali City","authors":"Ruth Dusabe, A. Muhayimana, Patrice Mujawimana, P. Meharry","doi":"10.4314/rjmhs.v3i2.3","DOIUrl":null,"url":null,"abstract":"Background \nNoise in the neonatal intensive care unit (NICU) has an impact on the developmental progress of neonates, especially preterm. Technology advancement has improved the life of preterm neonates, but also changed NICU into a noisy place. \nObjective \nTo measure the noise levels and identify its sources in NICU at selected public hospitals in Kigali city` \nMethods \nA quantitative cross-sectional descriptive study. A sound level meter was used in recording the Sound level in six different locations of the NICUs at five different times. An observational checklist was used to identify possible sources of noise. Data were analysed using descriptive and inferential statistics (ANOVA). \nResults \nSound levels recorded in all the NICUs were high ranging from 61.8 decibel (dB) to 77.0 dB, greater than the 45 dB recommended by the American Association of Pediatrics (AAP). The maximum noise level was 77.0 dB. Ward rounds had the highest noise levels, and lunchtime had the lowest noise levels in all hospitals. Noise levels were high at the station near the entrance in all NICU rooms. \nConclusion \nIn all NICUs, the noise level generated was greater than the standard limits established by AAP. Neonates need noise-free environment as excess noise has an impact on their wellbeing. \nRwanda J Med Health Sci 2020;3(2):115-127","PeriodicalId":315881,"journal":{"name":"Rwanda Journal of Medicine and Health Sciences","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rwanda Journal of Medicine and Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/rjmhs.v3i2.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background Noise in the neonatal intensive care unit (NICU) has an impact on the developmental progress of neonates, especially preterm. Technology advancement has improved the life of preterm neonates, but also changed NICU into a noisy place. Objective To measure the noise levels and identify its sources in NICU at selected public hospitals in Kigali city` Methods A quantitative cross-sectional descriptive study. A sound level meter was used in recording the Sound level in six different locations of the NICUs at five different times. An observational checklist was used to identify possible sources of noise. Data were analysed using descriptive and inferential statistics (ANOVA). Results Sound levels recorded in all the NICUs were high ranging from 61.8 decibel (dB) to 77.0 dB, greater than the 45 dB recommended by the American Association of Pediatrics (AAP). The maximum noise level was 77.0 dB. Ward rounds had the highest noise levels, and lunchtime had the lowest noise levels in all hospitals. Noise levels were high at the station near the entrance in all NICU rooms. Conclusion In all NICUs, the noise level generated was greater than the standard limits established by AAP. Neonates need noise-free environment as excess noise has an impact on their wellbeing. Rwanda J Med Health Sci 2020;3(2):115-127
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基加利市选定公立医院新生儿重症监护病房的噪声水平及其来源
新生儿重症监护病房(NICU)的噪音对新生儿,尤其是早产儿的发育进程有影响。科技进步改善了早产儿的生活,也把新生儿重症监护病房变成了一个嘈杂的地方。目的了解基加利市部分公立医院新生儿重症监护室噪声水平及噪声源。方法采用定量横断面描述性研究。用声级计记录新生儿重症监护病房6个不同位置5个不同时间的声级。使用一份观察清单来确定可能的噪声源。数据分析采用描述性和推断性统计(ANOVA)。结果新生儿重症监护病房的声级均为61.8 ~ 77.0 dB,高于美国儿科协会(AAP)推荐的45 dB。最大噪音水平为77.0 dB。在所有医院中,查房的噪音水平最高,而午餐时间的噪音水平最低。车站入口附近所有新生儿重症监护室的噪音水平都很高。结论所有新生儿重症监护病房产生的噪声水平均大于美国儿科学会(AAP)制定的标准限值。新生儿需要无噪音的环境,因为过多的噪音会影响他们的健康。卢旺达医学与健康科学,2020;3(2):115-127
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Psychology of Abortion: A Qualitative Exploration of Women’s Quality of Life after Termination of Pregnancy Service Provision Exploring Perceptions about Enablers of Women’s Attendance and Adherence to the Recommended Antenatal Care Visits in Rwanda: A Qualitative Study Lived Experiences of Adolescents with HIV in Rwanda: A Phenomenology Study Knowledge about Vitamin D among General Population in Baghdad City Effectiveness of Smartphone Application “Gororokapp” for Type 2 Diabetes Patients’ Self-Management in Rwanda: A Randomized Controlled Trial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1