Kejian Shi, Yidong Zhu, Xinyu Zhang, Ye Tian, Wei Du, Xiaoxiao Hu
{"title":"Research on early warning and location method of distribution network line fault","authors":"Kejian Shi, Yidong Zhu, Xinyu Zhang, Ye Tian, Wei Du, Xiaoxiao Hu","doi":"10.1109/ACPEE51499.2021.9437004","DOIUrl":null,"url":null,"abstract":"For improving the power supply reliability of distribution network and build a strong, intelligent and stable power supply network, a line fault early warning and location method suitable for medium voltage distribution network is proposed. Combined with the distribution and typical characteristics of distribution network line fault in a city, the formation mechanism of line fault is analyzed, the mathematical model of fault early warning location discrimination is constructed, and the line fault early warning and location method of distribution network is developed. The results show that the distribution network line fault early warning positioning method can accurately identify the location of insulation hidden danger, the positioning accuracy is less than 20 meters, and the accuracy rate of insulation hidden danger early warning is more than 90%. It can effectively reduce the failure rate of distribution network, reduce the time of power failure, and improve the efficiency High power supply reliability.","PeriodicalId":127882,"journal":{"name":"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 6th Asia Conference on Power and Electrical Engineering (ACPEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACPEE51499.2021.9437004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
For improving the power supply reliability of distribution network and build a strong, intelligent and stable power supply network, a line fault early warning and location method suitable for medium voltage distribution network is proposed. Combined with the distribution and typical characteristics of distribution network line fault in a city, the formation mechanism of line fault is analyzed, the mathematical model of fault early warning location discrimination is constructed, and the line fault early warning and location method of distribution network is developed. The results show that the distribution network line fault early warning positioning method can accurately identify the location of insulation hidden danger, the positioning accuracy is less than 20 meters, and the accuracy rate of insulation hidden danger early warning is more than 90%. It can effectively reduce the failure rate of distribution network, reduce the time of power failure, and improve the efficiency High power supply reliability.