Study on Single-phase Ground Fault Location of Distribution Network Based on MDS and DBSCAN Clustering

Zhijun Mu, Yuguang Wu, Hongxu Yin, Zhigang Liu, Chunxiu Liu
{"title":"Study on Single-phase Ground Fault Location of Distribution Network Based on MDS and DBSCAN Clustering","authors":"Zhijun Mu, Yuguang Wu, Hongxu Yin, Zhigang Liu, Chunxiu Liu","doi":"10.23919/CCC50068.2020.9188678","DOIUrl":null,"url":null,"abstract":"When a single-phase grounding fault occurs in the distribution network with DG (Distributed Generation), the fault location is mainly completed by the switch information at the node. This method cannot make full use of the fault information and cannot be applied to the intelligent distribution network under the background of massive data. To solve the above problems, a single-phase grounding fault location method based on MDS (Multidimensional Scaling) and DBSCAN (Density- Based Spatial Clustering of Applications with Noise) is proposed. The simulation results show that the proposed method is not affected by fault location, fault resistance, fault angle and line type, and the fault location results are accurate, which can effectively use the fault information.","PeriodicalId":255872,"journal":{"name":"2020 39th Chinese Control Conference (CCC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 39th Chinese Control Conference (CCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CCC50068.2020.9188678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

When a single-phase grounding fault occurs in the distribution network with DG (Distributed Generation), the fault location is mainly completed by the switch information at the node. This method cannot make full use of the fault information and cannot be applied to the intelligent distribution network under the background of massive data. To solve the above problems, a single-phase grounding fault location method based on MDS (Multidimensional Scaling) and DBSCAN (Density- Based Spatial Clustering of Applications with Noise) is proposed. The simulation results show that the proposed method is not affected by fault location, fault resistance, fault angle and line type, and the fault location results are accurate, which can effectively use the fault information.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于MDS和DBSCAN聚类的配电网单相接地故障定位研究
当有DG (Distributed Generation)的配电网发生单相接地故障时,故障定位主要依靠节点的开关信息来完成。该方法不能充分利用故障信息,不能应用于海量数据背景下的智能配电网。针对上述问题,提出了一种基于MDS(多维尺度)和DBSCAN(基于密度的带噪声应用空间聚类)的单相接地故障定位方法。仿真结果表明,该方法不受故障位置、故障电阻、故障角度和线路类型的影响,故障定位结果准确,能够有效地利用故障信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Matrix-based Algorithm for the LS Design of Variable Fractional Delay FIR Filters with Constraints MPC Control and Simulation of a Mixed Recovery Dual Channel Closed-Loop Supply Chain with Lead Time Fractional-order ADRC framework for fractional-order parallel systems A Moving Target Tracking Control and Obstacle Avoidance of Quadrotor UAV Based on Sliding Mode Control Using Artificial Potential Field and RBF Neural Networks Finite-time Pinning Synchronization and Parameters Identification of Markovian Switching Complex Delayed Network with Stochastic Perturbations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1