{"title":"Harmonics Suppression in Distribution Networks composed of Uninterruptible Power Supply Systems","authors":"A. Waqar, M. Amir, Imtiaz Alam, Z. Khan, Sohaib Ali Khan, Tausif Zahid, M. Zahid","doi":"10.1109/ICEEST48626.2019.8981704","DOIUrl":null,"url":null,"abstract":"In recent years, utilization of power electronic converters has been drastically increased. These converters act like non-linear loads for utility grid. Such non-linear loads distort the supply current through injection of harmonics. One such example is the uninterruptible power supply (UPS) system, which is a major source of current harmonics. These harmonics affect the performance of distribution transformers in terms of losses, heating of core, stress on insulation and tripping of the protection relays. In this paper, the increase of total harmonic distortion (THD) of the supply current, caused by uncontrolled rectifiers used in UPS systems, has been minimized. Two methods including passive filters (PF) and active filters (AF) have been applied to minimize the THD. The simulations have been performed in MATLAB/Simulink environment where the results of both schemes have been compared under various load conditions (RL and unbalanced load). It has been found that AF provides a better solution as compared to PF for such load conditions.","PeriodicalId":201513,"journal":{"name":"2019 4th International Conference on Emerging Trends in Engineering, Sciences and Technology (ICEEST)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 4th International Conference on Emerging Trends in Engineering, Sciences and Technology (ICEEST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEST48626.2019.8981704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In recent years, utilization of power electronic converters has been drastically increased. These converters act like non-linear loads for utility grid. Such non-linear loads distort the supply current through injection of harmonics. One such example is the uninterruptible power supply (UPS) system, which is a major source of current harmonics. These harmonics affect the performance of distribution transformers in terms of losses, heating of core, stress on insulation and tripping of the protection relays. In this paper, the increase of total harmonic distortion (THD) of the supply current, caused by uncontrolled rectifiers used in UPS systems, has been minimized. Two methods including passive filters (PF) and active filters (AF) have been applied to minimize the THD. The simulations have been performed in MATLAB/Simulink environment where the results of both schemes have been compared under various load conditions (RL and unbalanced load). It has been found that AF provides a better solution as compared to PF for such load conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不间断供电系统组成的配电网谐波抑制
近年来,电力电子变换器的利用率急剧提高。这些变流器的作用类似于公用电网的非线性负载。这种非线性负载通过注入谐波扭曲了供电电流。其中一个例子是不间断电源(UPS)系统,它是电流谐波的主要来源。这些谐波在损耗、铁芯发热、绝缘应力和保护继电器跳闸方面影响配电变压器的性能。在本文中,已经最小化了由UPS系统中使用的不受控制的整流器引起的电源电流的总谐波失真(THD)的增加。采用无源滤波器(PF)和有源滤波器(AF)两种方法来最小化THD。在MATLAB/Simulink环境下进行了仿真,比较了两种方案在不同负载条件下(RL和不平衡负载)的结果。已经发现AF提供了一个更好的解决方案,相比于PF这样的负载条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Challenges in Adoption of Blockchain in Developing Countries Energy Generation Potential through utilization of Piezoelectric materials in Smart Motorway System (SMS) of Pakistan VLCS: A Novel Clock Synchronization Technique for TDMA-based MAC Protocols in VANETs Assessment of Energy Savings through Technological Innovation: A case Study for Residential Sector of Pakistan Comparison of Camera and Laser Scanner based 3D Point Cloud
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1