{"title":"Wide-area monitoring and control at Hydro-Quebec: past, present and future","authors":"I. Kamwa, J. Béland, G. Trudel, R. Grondin, C. Lafond, D. McNabb","doi":"10.1109/PES.2006.1709097","DOIUrl":null,"url":null,"abstract":"This paper recalls the 30-year history of wide-area measurements at Hydro-Quebec. At present, a state-of-the art, eight-PMU-based wide-area monitoring system commissioned in 2004 is on line, feeding the EMS with GPS-synchronized angles, frequencies, and harmonic distortion measurements from key 735-kV buses. Specific to Hydro-Quebec is the current use of one such system for frequency regulation reporting and control-room implementation of preventive measures against geomagnetic storm-induced contingencies. Building on this experience, the Hydro-Quebec research institute, together with TransEnergie, is developing advanced applications which, in the long term, will go beyond active monitoring to safely initiate targeted control actions aimed at extending system power transfer limits with respect to both transient and long-term stability. In addition to the major improvement in inter-area mode damping shown previously by the authors, this paper demonstrates that, surprisingly, wide-area control of static VAr compensators (SVC) will also vastly extend the first-swing stability margins. Finally, initial results on a wide-area measurement-based secondary voltage control of the extensive park of dynamic shunt compensators in our grid using a single pilot voltage from the load center are very encouraging","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"733 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"116","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 116

Abstract

This paper recalls the 30-year history of wide-area measurements at Hydro-Quebec. At present, a state-of-the art, eight-PMU-based wide-area monitoring system commissioned in 2004 is on line, feeding the EMS with GPS-synchronized angles, frequencies, and harmonic distortion measurements from key 735-kV buses. Specific to Hydro-Quebec is the current use of one such system for frequency regulation reporting and control-room implementation of preventive measures against geomagnetic storm-induced contingencies. Building on this experience, the Hydro-Quebec research institute, together with TransEnergie, is developing advanced applications which, in the long term, will go beyond active monitoring to safely initiate targeted control actions aimed at extending system power transfer limits with respect to both transient and long-term stability. In addition to the major improvement in inter-area mode damping shown previously by the authors, this paper demonstrates that, surprisingly, wide-area control of static VAr compensators (SVC) will also vastly extend the first-swing stability margins. Finally, initial results on a wide-area measurement-based secondary voltage control of the extensive park of dynamic shunt compensators in our grid using a single pilot voltage from the load center are very encouraging
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
魁北克水电广域监测和控制:过去、现在和未来
本文回顾了魁北克水电30年广域测量的历史。目前,一个最先进的、基于8个pmu的广域监测系统于2004年投入使用,为EMS提供来自735千伏关键母线的gps同步角度、频率和谐波失真测量数据。魁北克水电局目前使用一种这样的系统,用于频率调节报告和控制室实施预防措施,以防止地磁风暴引起的突发事件。基于这一经验,Hydro-Quebec研究所与TransEnergie一起正在开发先进的应用程序,从长远来看,这些应用程序将超越主动监测,安全启动有针对性的控制行动,旨在延长系统暂态和长期稳定性方面的电力传输限制。除了作者先前显示的区域间模态阻尼的主要改进之外,本文还表明,令人惊讶的是,静态无功补偿器(SVC)的广域控制也将极大地扩展首摆稳定裕度。最后,利用负载中心的单个导频电压对电网中大量动态并联补偿器进行了基于广域测量的二次电压控制,初步结果令人鼓舞
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Decision making under uncertainty in electricity markets Gas insulated substation GIS Developing a comprehensive substation cyber security and data management solution Coordinated control strategy for UPQC and its verification A concept for dual gaseous and electric energy transmission
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1