Elimination of the Phase Mismatch Error in PP Probe Using Synchronous Measurement Technique

M. Raczyński
{"title":"Elimination of the Phase Mismatch Error in PP Probe Using Synchronous Measurement Technique","authors":"M. Raczyński","doi":"10.14313/par_244/35","DOIUrl":null,"url":null,"abstract":"The paper presents a modification of the pressure-pressure (PP) sound intensity measurement method. In the proposed solution simultaneous measurement with a pair of microphones (used in the classical PP probe) is replaced by a sequence of measurements taken with a single microphone placed in successive positions. This approach requires an additional (reference) microphone to synchronize the successive measurements. Although, in the process of calculating the sound intensity only the signal from the measurement microphone is used. Thanks of this the errors associated with differences in the frequency responses of the measurement microphones (especially phase mismatch error) that occurs in the classical PP method are eliminated. This approach simultaneously increases the random error and limits the measurements to periodic signals only. The article presents the principle of operation of the classical PP probe and the currently used methods of phase mismatch error elimination based on pre-calibration of the probe. Next, the theoretical basis of the proposed measurement method is described. To verify the effectiveness of phase mismatch error elimination in the proposed method, an experiment was conducted. It consisted in estimation the angle of incidence of an acoustic wave under controlled conditions in an anechoic chamber. The measurement was carried out with the classical PP probe and with the modified method. Measurements were made for different sound sources (a loudspeaker set and a small electrical device). In the final part of the paper, the results are discussed, both methods (classical and modified) are compared and potential applications of the proposed method are indicated.","PeriodicalId":383231,"journal":{"name":"Pomiary Automatyka Robotyka","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pomiary Automatyka Robotyka","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14313/par_244/35","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The paper presents a modification of the pressure-pressure (PP) sound intensity measurement method. In the proposed solution simultaneous measurement with a pair of microphones (used in the classical PP probe) is replaced by a sequence of measurements taken with a single microphone placed in successive positions. This approach requires an additional (reference) microphone to synchronize the successive measurements. Although, in the process of calculating the sound intensity only the signal from the measurement microphone is used. Thanks of this the errors associated with differences in the frequency responses of the measurement microphones (especially phase mismatch error) that occurs in the classical PP method are eliminated. This approach simultaneously increases the random error and limits the measurements to periodic signals only. The article presents the principle of operation of the classical PP probe and the currently used methods of phase mismatch error elimination based on pre-calibration of the probe. Next, the theoretical basis of the proposed measurement method is described. To verify the effectiveness of phase mismatch error elimination in the proposed method, an experiment was conducted. It consisted in estimation the angle of incidence of an acoustic wave under controlled conditions in an anechoic chamber. The measurement was carried out with the classical PP probe and with the modified method. Measurements were made for different sound sources (a loudspeaker set and a small electrical device). In the final part of the paper, the results are discussed, both methods (classical and modified) are compared and potential applications of the proposed method are indicated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同步测量技术消除PP探头相位失配误差
本文提出了一种对压力-压力(PP)声强测量方法的改进。在提出的解决方案中,用一对麦克风(在经典PP探针中使用)进行的同时测量被用放置在连续位置的单个麦克风进行的一系列测量所取代。这种方法需要一个额外的(参考)麦克风来同步连续的测量。虽然在计算声强的过程中只使用来自测量麦克风的信号。由于这种方法,消除了传统PP方法中与测量麦克风频率响应差异相关的误差(特别是相位失配误差)。这种方法同时增加了随机误差,并限制了周期信号的测量。介绍了经典PP测头的工作原理,以及目前常用的基于测头预标定的相位失配误差消除方法。其次,介绍了所提出的测量方法的理论基础。为了验证该方法消除相位失配误差的有效性,进行了实验。它包括在消声室中控制条件下对声波入射角的估计。用经典的PP探针和改进的方法进行了测量。测量了不同的声源(扬声器组和小型电气设备)。最后对结果进行了讨论,对两种方法(经典方法和改进方法)进行了比较,并指出了所提方法的潜在应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Analysis of Selected Calibration Methods for a Thermal Imaging Camera with a Cooled Detector Operating in the MWIR Range A Method of Measurement of Minimum Resolvable Temperature Difference as a Function of Magnification and Defocusing of a Thermal Camera Study on the Influence of an UGV Suspension System on Camera Motion of the Teleoperation System Tuning the Heading Controller for the Ship’s Autopilot Generation of Spatial Terrain Using the Hermes Editor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1