KNEE JOINT OF THREE-HINGED GLUED TIMBER PORTAL FRAME EXECUTED AS JOINT ON GLUED-IN RODS

А.Ya. Naichuk
{"title":"KNEE JOINT OF THREE-HINGED GLUED TIMBER PORTAL FRAME EXECUTED AS JOINT ON GLUED-IN RODS","authors":"А.Ya. Naichuk","doi":"10.31650/2707-3068-2021-25-92-102","DOIUrl":null,"url":null,"abstract":"In the modern construction of buildings and structures there are many constructive solutions for connecting the rafter with the column of wooden three-hinged portal frames. One of these constructive solutions is the use of knee joints executed as joint on glued-in rods. Despite the accumulated experience in the construction of buildings using timber structures with joints on glued-in rods, there are still urgent tasks to improve the technology of their manufacture and calculation models. The purpose of this work was to conduct experimental and theoretical studies of the knee joint executed as joint on glued-in rods to determine the stress-strain state of the timber in the connection region. To develop of proposals for improving knee joint executed as joint on glued-in rods. The study of the stress-strain state of the knee joint was carried out by solving a plane problem of the theory of elasticity using a software package based on the finite element method. In the software package used, procedures are implemented to take into account the anisotropy of the mechanical properties of wood, the violation of contact between the surfaces of the elements connected in the knee joint. Experimental studies were carried out by the method of static loading of a prototype of a knee joint made in full size, which in its geometric parameters and material properties corresponded to the CE model. As a result of the conducted studies, it was found that in the stretched zone of the knee joint, the glued rods of the rafter and the column are characterized by a significant uneven distribution of forces, in addition, the rods are subjected to compression, tension and bending. The most loaded are the rods located at the maximum distance from the joint of the rafter and the column. The distribution of forces in the rods of the compressed zone is close to uniform. The stress distribution along the length of the inclined rods of the embedded parts is characterized by a large unevenness. Based on the analysis of the stress-strain state of the knee joint of the frame, a new design solution is proposed in terms of the number of glued-in rods and their spacing.","PeriodicalId":365885,"journal":{"name":"Modern structures of metal and wood","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern structures of metal and wood","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31650/2707-3068-2021-25-92-102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the modern construction of buildings and structures there are many constructive solutions for connecting the rafter with the column of wooden three-hinged portal frames. One of these constructive solutions is the use of knee joints executed as joint on glued-in rods. Despite the accumulated experience in the construction of buildings using timber structures with joints on glued-in rods, there are still urgent tasks to improve the technology of their manufacture and calculation models. The purpose of this work was to conduct experimental and theoretical studies of the knee joint executed as joint on glued-in rods to determine the stress-strain state of the timber in the connection region. To develop of proposals for improving knee joint executed as joint on glued-in rods. The study of the stress-strain state of the knee joint was carried out by solving a plane problem of the theory of elasticity using a software package based on the finite element method. In the software package used, procedures are implemented to take into account the anisotropy of the mechanical properties of wood, the violation of contact between the surfaces of the elements connected in the knee joint. Experimental studies were carried out by the method of static loading of a prototype of a knee joint made in full size, which in its geometric parameters and material properties corresponded to the CE model. As a result of the conducted studies, it was found that in the stretched zone of the knee joint, the glued rods of the rafter and the column are characterized by a significant uneven distribution of forces, in addition, the rods are subjected to compression, tension and bending. The most loaded are the rods located at the maximum distance from the joint of the rafter and the column. The distribution of forces in the rods of the compressed zone is close to uniform. The stress distribution along the length of the inclined rods of the embedded parts is characterized by a large unevenness. Based on the analysis of the stress-strain state of the knee joint of the frame, a new design solution is proposed in terms of the number of glued-in rods and their spacing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三铰胶合木门式框架膝关节在胶合杆上执行
在现代建筑和构筑物的建造中,有许多建设性的解决方案将椽子与木制三铰门框的柱连接起来。这些建设性的解决方案之一是使用膝关节执行的关节粘在棒。虽然在木结构粘接施工方面积累了一定的经验,但其制造技术和计算模型的改进仍是亟待解决的问题。本工作的目的是对膝关节作为粘接杆的接头进行实验和理论研究,以确定连接区域木材的应力-应变状态。提出了改进膝关节作为粘接棒关节的建议。利用基于有限元法的软件包求解弹性理论的平面问题,对膝关节的应力-应变状态进行了研究。在使用的软件包中,执行的程序考虑了木材机械性能的各向异性,膝关节中连接的元素表面之间的接触破坏。采用静载荷法对全尺寸膝关节原型进行了实验研究,该原型在几何参数和材料性能上均与CE模型相符。研究结果表明,在膝关节拉伸区,梁、柱胶合杆受力分布不均匀,且受压、受拉、受弯。荷载最大的是位于离梁和柱的连接处最大距离处的杆。压缩区的杆内力的分布接近均匀。沿预埋件斜杆长度方向的应力分布具有较大的不均匀性。在分析车架膝关节应力应变状态的基础上,从粘接杆数和间距两方面提出了一种新的设计方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THE FEATURES OF DETERMINATION OF SEISMIC LOADS ON STEEL SILOS WITH A FLAT BOTTOM ACCORDING TO DBN V.2.6-221:2021 REGARDING THE IMPROVEMENT OF CURRENT NORMATIVE DOCUMENTS FOR THE CALCULATION OF BENDING WOODEN ELEMENTS AND STRUCTURES THE DECREASE IN THE LEVEL OF CORROSION HAZARD IN THE RATIONAL DESIGN OF METAL STRUCTURES GENERALIZED MODEL OF THE ACTUAL WORK OF DECIDOUS AND CONIFEROUS WOOD UNDER AXIAL COMPRESSION ALONG THE FIBERS INFLUENCE OF BOLTED SPLICE CONNECTIONS ON THE GLOBAL BEHAVIOUR OF STEEL LATTICE TELECOMMUNICATION TOWERS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1