High voltage DC ramp testing as a diagnostic of stator insulation condition

H. Sedding, B. Gupta, W. McDermid, J. Bromley, R. Schwabe, L. D, J. Stein
{"title":"High voltage DC ramp testing as a diagnostic of stator insulation condition","authors":"H. Sedding, B. Gupta, W. McDermid, J. Bromley, R. Schwabe, L. D, J. Stein","doi":"10.1109/ELINSL.2004.1380630","DOIUrl":null,"url":null,"abstract":"Machine users have used high voltage DC ramp testing of stator winding insulation for almost 40 years. Traditionally, this test has proved useful in assessing the condition of the groundwall insulation and in finding defects such as tape separation and lack of resin cure. Recently, some organizations have claimed that the high voltage DC ramp test may also be used to detect delamination in the groundwall insulation. This concept has also been incorporated into the latest revision of IEEE standard 95. However, to date, no theoretical basis exists to explain the effect on the V-I characteristic attributed to internal groundwall delamination. Thus, the use of DC ramp to detect internal delamination in groundwall remains somewhat controversial. A recent EPRI study involving high voltage DC ramp testing in the field and under laboratory conditions was performed as part of an investigation into the efficacy of the test as a detector of delamination inside groundwall. This work describes the investigation and the results obtained.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Machine users have used high voltage DC ramp testing of stator winding insulation for almost 40 years. Traditionally, this test has proved useful in assessing the condition of the groundwall insulation and in finding defects such as tape separation and lack of resin cure. Recently, some organizations have claimed that the high voltage DC ramp test may also be used to detect delamination in the groundwall insulation. This concept has also been incorporated into the latest revision of IEEE standard 95. However, to date, no theoretical basis exists to explain the effect on the V-I characteristic attributed to internal groundwall delamination. Thus, the use of DC ramp to detect internal delamination in groundwall remains somewhat controversial. A recent EPRI study involving high voltage DC ramp testing in the field and under laboratory conditions was performed as part of an investigation into the efficacy of the test as a detector of delamination inside groundwall. This work describes the investigation and the results obtained.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高压直流斜坡试验诊断定子绝缘状态
机器用户使用高压直流斜坡测试定子绕组绝缘已有近40年的历史。传统上,该测试已被证明在评估接地墙绝缘状况和发现胶带分离和缺乏树脂固化等缺陷方面是有用的。最近,一些机构声称高压直流斜坡试验也可用于检测地墙绝缘的分层。这一概念也被纳入IEEE标准95的最新修订版。然而,到目前为止,还没有理论依据来解释内底壁脱层对V-I特性的影响。因此,使用直流斜坡检测地壁内部分层仍然存在一些争议。EPRI最近的一项研究涉及在现场和实验室条件下进行的高压直流斜坡测试,作为调查该测试作为地墙内部分层检测器的有效性的一部分。本工作描述了调查和所得结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transmission power cables PD detection at damped AC voltages Improvements to the performance of silicone rubber housed composite bushings by means of a resistive coating Further experience in the use of existing RTDs in windings of motors generators for the measurement of partial discharges Effect of thermally stimulated discharges on partial discharges and tree growth in PMMA A review of artificial contamination withstand test methods of high voltage outdoor insulators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1