COMPARISON BETWEEN SOLAR THERMAL-POWERED ABSORPTION REFRIGERATION CYCLE AND PHOTOVOLTAIC-POWERED COOLING TECHNOLOGIES APPLIED TO DATA CENTERs

A. Belizário, J. Simões-Moreira
{"title":"COMPARISON BETWEEN SOLAR THERMAL-POWERED ABSORPTION REFRIGERATION CYCLE AND PHOTOVOLTAIC-POWERED COOLING TECHNOLOGIES APPLIED TO DATA CENTERs","authors":"A. Belizário, J. Simões-Moreira","doi":"10.5380/reterm.v21i2.87918","DOIUrl":null,"url":null,"abstract":"The air conditioning system of a Data Center is a great challenge for mechanical engineers. At the same time, it is fundamental for computer safety, it is a great energy consumer. Considering that, the present work carried out an analysis in which a solar-powered absorption refrigeration cycle system is combined with a conventional electrical chiller system. The proposed system also introduces the use of PV panels to generate electricity to power the electric chiller. A decision algorithm was developed based on local solar parametric data and cooling demand. A case study was analyzed for a typical data center located in the city of São Paulo, Brazil. Electrical specific installed power demands of 0.5, 1.0, 2.0, 4.0, and 8.0 kW/m² at half and total load were studied. Local solar irradiation and temperature indexes were based on the data obtained from ASHRAE [1]. The results show that, for a typical year, the absorption solar system performs better than the photovoltaic system in most cases (0.5, 1.0, 4.0, and 8.0 kW/m²), except when the baseline of the installation operates near the optimum point of the consumption curve of the chiller, which occurs at 2 kW/m². Finally, the study shows that air conditioning systems powered by solar energy are a great alternative to reduce the energy consumption and operational costs of a Data Center.","PeriodicalId":106768,"journal":{"name":"Revista de Engenharia Térmica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de Engenharia Térmica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5380/reterm.v21i2.87918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The air conditioning system of a Data Center is a great challenge for mechanical engineers. At the same time, it is fundamental for computer safety, it is a great energy consumer. Considering that, the present work carried out an analysis in which a solar-powered absorption refrigeration cycle system is combined with a conventional electrical chiller system. The proposed system also introduces the use of PV panels to generate electricity to power the electric chiller. A decision algorithm was developed based on local solar parametric data and cooling demand. A case study was analyzed for a typical data center located in the city of São Paulo, Brazil. Electrical specific installed power demands of 0.5, 1.0, 2.0, 4.0, and 8.0 kW/m² at half and total load were studied. Local solar irradiation and temperature indexes were based on the data obtained from ASHRAE [1]. The results show that, for a typical year, the absorption solar system performs better than the photovoltaic system in most cases (0.5, 1.0, 4.0, and 8.0 kW/m²), except when the baseline of the installation operates near the optimum point of the consumption curve of the chiller, which occurs at 2 kW/m². Finally, the study shows that air conditioning systems powered by solar energy are a great alternative to reduce the energy consumption and operational costs of a Data Center.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
太阳能热能吸收式制冷循环与光伏制冷技术在数据中心应用的比较
数据中心的空调系统对机械工程师来说是一个很大的挑战。同时,它是计算机安全的基础,是一个巨大的能源消耗。考虑到这一点,本文对太阳能吸收式制冷循环系统与传统电制冷系统相结合进行了分析。拟议的系统还引入了使用PV板来发电,为电动冷却器供电。提出了一种基于当地太阳能参数数据和制冷需求的决策算法。本文分析了一个位于巴西圣保罗市的典型数据中心的案例研究。研究了半负荷和总负荷下0.5、1.0、2.0、4.0和8.0 kW/m²的电气特定安装功率需求。局部太阳辐照度和温度指标基于ASHRAE[1]获得的数据。结果表明,在典型年份,除了安装基线运行在制冷机消耗曲线的最佳点附近(2 kW/m²)外,吸收式太阳能系统在大多数情况下(0.5、1.0、4.0和8.0 kW/m²)优于光伏系统。最后,该研究表明,太阳能驱动的空调系统是一个很好的替代方案,可以减少数据中心的能源消耗和运营成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THERMODYNAMIC AND ECONOMIC ANALYSIS OF A BIOGAS -FUELED MICRO GAS TURBINE WITH COMPRESSOR PHOTOVOLTAIC DRIVE STUDY OF MECHANICAL PROPERTIES, MICROSTRUCTURE AND RESIDUAL STRESS BY X-RAY DIFFRACTION IN WELDED JOINTS OF DUPLEX STEEL UNS S 31803 BY COATED ELECTRODE A PROPOSAL FOR A HYBRID POWER TRAIN FOR A TRUCK NUMERICAL ANALYSIS OF CIRCULATION AND DISPERSION OF POLLUTANTS IN VENTILATED BUILDINGS UNDER NON-ISOTHERMAL CONDITIONS THERMODYNAMIC PROPERTIES CALCULATION USING A MULTIOBJECTIVE APPROACH IN ESTIMATING THE PARAMETERS OF THE GEOS3C EQUATION OF STATE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1