{"title":"An Unbiased Technique For Automatic Estimation Of Vessel Contours In Angiograms","authors":"M. Figueiredo, J. Leitão","doi":"10.1109/NSSMIC.1993.701843","DOIUrl":null,"url":null,"abstract":"AbatTactAccurate and fully automatic assessment of artery dimensions in angiograms has been sought as a diagnostic tool, in particular for coronary heart disease. We propose a new technique to estimate vessel borders in angiographic images. Unlike in previous approaches, the obtained edge estimates are unbiased, this being of primordial importance since quantitative analysis is the goal. Another important feature of the proposed estimator is that no constant background is assumed, making it well suited for noxisubtracted angiograms. The key aspect of our approach is that the smoothness constraint is not used to smooth or i n some other way modify the estimates directly derived from the image (which would introduce bias) but rather elect (without modifying) candidate estimates. As a result, tlie selected points, if correct, are unbiased estimates. Even at low contrast segments and in tlie vicinity of artifacts, the true border points still correspond to (possibly faint) local maxima of the edge operator, wliicli can be correctly chosen if the surrounding context is taken into account. Robustness against unknown background is provided by tlie use a morphological edge detector rather than some linear operator such as a matched filter wliicli assumes flat background.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
AbatTactAccurate and fully automatic assessment of artery dimensions in angiograms has been sought as a diagnostic tool, in particular for coronary heart disease. We propose a new technique to estimate vessel borders in angiographic images. Unlike in previous approaches, the obtained edge estimates are unbiased, this being of primordial importance since quantitative analysis is the goal. Another important feature of the proposed estimator is that no constant background is assumed, making it well suited for noxisubtracted angiograms. The key aspect of our approach is that the smoothness constraint is not used to smooth or i n some other way modify the estimates directly derived from the image (which would introduce bias) but rather elect (without modifying) candidate estimates. As a result, tlie selected points, if correct, are unbiased estimates. Even at low contrast segments and in tlie vicinity of artifacts, the true border points still correspond to (possibly faint) local maxima of the edge operator, wliicli can be correctly chosen if the surrounding context is taken into account. Robustness against unknown background is provided by tlie use a morphological edge detector rather than some linear operator such as a matched filter wliicli assumes flat background.