Effect of Polymerization Time and Shade on the Depth of Cure of Nano-Hybrid Resin Composites

Noha Abdullah Bin Jabr, Wacim Nassouh Al-Saidi, Ibtessam Abdullah Bin Jabr, Roula Al-Bounni
{"title":"Effect of Polymerization Time and Shade on the Depth of Cure of Nano-Hybrid Resin Composites","authors":"Noha Abdullah Bin Jabr, Wacim Nassouh Al-Saidi, Ibtessam Abdullah Bin Jabr, Roula Al-Bounni","doi":"10.1055/s-0041-1726169","DOIUrl":null,"url":null,"abstract":"Abstract Objective The effect of polymerization time and resin shade on the depth of cure (DOC) of two nano-hybrid resin composites (Filtek Z250 XT and IPS Empress Direct) was evaluated and compared. Materials and Methods Sixty specimens were prepared from two shades (A1 and A3) of the resin composites. The specimens were allocated into two groups that were further divided into three subgroups depending on the polymerization time (20, 40, and 60 sec; n = 5). After that, the DOC was evaluated by calculating the polymerized part of the specimen’s thickness to the nearest (0.01 mm) using a high-accuracy micrometer. Each specimen was measured three times, and the corresponding mean reading (in mm) was divided by two to obtain the DOC. The data were analyzed using SPSS software, version 20. Descriptive statistics followed by three-way analysis of variance was applied. Multiple comparisons were made using Scheffe post hoc tests (α = 0.05). Results Filtek Z250 XT-A1-60sec presented with the greatest DOC (7.42 ± 0.47 mm), and the lowest DOC was obtained with IPS Empress-A3-20sec (2.31 ± 0.21 mm). The mean DOC of Filtek Z250 XT and IPS Empress Direct resin composites were 6.18 mm and 3.59 mm, respectively. Statistically significant (p < 0.05) difference was observed between the resin composites. The interaction between independent factors, namely composites, resin shade, and polymerization time, revealed that interaction between them contributed significantly to the DOC (p ≤0.05). However, the interaction between resin shade and the polymerization time was insignificant (p = 0.148). Conclusion Filtek Z250 XT demonstrated greater DOC than IPS Empress Direct resin composite. An increase in polymerization time significantly enhanced the DOC of the resin composites irrespective of the resin shade. Regardless of the resin composite tested, DOC was lower for darker shades (A3).","PeriodicalId":130020,"journal":{"name":"European Dental Research and Biomaterials Journal","volume":"125 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Dental Research and Biomaterials Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1726169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract Objective The effect of polymerization time and resin shade on the depth of cure (DOC) of two nano-hybrid resin composites (Filtek Z250 XT and IPS Empress Direct) was evaluated and compared. Materials and Methods Sixty specimens were prepared from two shades (A1 and A3) of the resin composites. The specimens were allocated into two groups that were further divided into three subgroups depending on the polymerization time (20, 40, and 60 sec; n = 5). After that, the DOC was evaluated by calculating the polymerized part of the specimen’s thickness to the nearest (0.01 mm) using a high-accuracy micrometer. Each specimen was measured three times, and the corresponding mean reading (in mm) was divided by two to obtain the DOC. The data were analyzed using SPSS software, version 20. Descriptive statistics followed by three-way analysis of variance was applied. Multiple comparisons were made using Scheffe post hoc tests (α = 0.05). Results Filtek Z250 XT-A1-60sec presented with the greatest DOC (7.42 ± 0.47 mm), and the lowest DOC was obtained with IPS Empress-A3-20sec (2.31 ± 0.21 mm). The mean DOC of Filtek Z250 XT and IPS Empress Direct resin composites were 6.18 mm and 3.59 mm, respectively. Statistically significant (p < 0.05) difference was observed between the resin composites. The interaction between independent factors, namely composites, resin shade, and polymerization time, revealed that interaction between them contributed significantly to the DOC (p ≤0.05). However, the interaction between resin shade and the polymerization time was insignificant (p = 0.148). Conclusion Filtek Z250 XT demonstrated greater DOC than IPS Empress Direct resin composite. An increase in polymerization time significantly enhanced the DOC of the resin composites irrespective of the resin shade. Regardless of the resin composite tested, DOC was lower for darker shades (A3).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚合时间和荫蔽对纳米杂化树脂复合材料固化深度的影响
摘要目的比较聚合时间和树脂色度对两种纳米杂化树脂复合材料(Filtek Z250 XT和IPS Empress Direct)固化深度(DOC)的影响。材料与方法采用A1和A3两种颜色的树脂复合材料制备了60个样品。将样品分为两组,根据聚合时间(20,40和60秒)进一步分为三个亚组;n = 5)。之后,通过使用高精度千分尺计算样品的聚合部分厚度至最接近(0.01 mm)来评估DOC。每个标本测量三次,相应的平均读数(mm)除以2得到DOC。数据分析采用SPSS软件,版本20。采用描述性统计和三向方差分析。采用Scheffe事后检验进行多重比较(α = 0.05)。结果Filtek Z250 XT-A1-60sec的DOC最大(7.42±0.47 mm), IPS皇后a3 -20sec的DOC最小(2.31±0.21 mm)。Filtek Z250 XT和IPS皇后直接树脂复合材料的平均DOC分别为6.18 mm和3.59 mm。两种树脂复合材料间差异有统计学意义(p < 0.05)。复合材料、树脂色度和聚合时间三者之间的相互作用表明,三者之间的相互作用对DOC有显著影响(p≤0.05)。而树脂色度与聚合时间的相互作用不显著(p = 0.148)。结论Filtek Z250 XT比IPS皇后直接树脂复合材料具有更高的DOC。无论树脂色度如何,增加聚合时间都能显著提高树脂复合材料的DOC。无论测试哪种树脂复合材料,深色的DOC都较低(A3)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Restorative Modalities for Structurally Compromised Teeth with Thin-walled Roots: A Literature Review The Effect of Correlation of Laboratory-Developed Test and Initial Symptoms and False Negatives in RT-PCR Strategies for COVID-19 Patients with Beta Variants Multipurpose Silicon-Based Toothpastes: Decision Making for a Better Oral Health The Oral Manifestations of SARS-CoV-2, Mucormycosis, and Leukemia in the Current Pandemic Assessment of the Level of Interleukin-12 in Gingival Crevicular Fluid of a Group of Patients with Aggressive Periodontitis and a Group of Healthy Subjects
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1