Performance of hybrid photovoltaic/thermal crop dryer in hot humid Nigerian region

Sampson Uzoma, N. Nwakuba, Kelechi E. Anyaoha
{"title":"Performance of hybrid photovoltaic/thermal crop dryer in hot humid Nigerian region","authors":"Sampson Uzoma, N. Nwakuba, Kelechi E. Anyaoha","doi":"10.5937/POLJTEH1902056U","DOIUrl":null,"url":null,"abstract":"This paper presents a study carried out to investigate the performance of a hybrid photovoltaic/thermal crop dryer in hot humid region of Umuagwo-Ohaji in the South-east region of Nigeria, through energy and exergy analyses, drying, electrical and thermal efficiencies, energy utilization and energy utilization ratio, sustainability indicators such as waste energy ratio (WER), sustainability index (SI) and improvement potential (IP). Drying experiments were conducted at varying inlet air temperatures (50, 60 and 70 o C), airflow rates (1.14, 2.29 and 3.43 kgs -1 ) and slice thicknesses (10, 15 and 20 mm) on 500g batch size of red pepper slices during sunshine periods. Results obtained show that the total and specific energy consumption for drying a batch of sliced red pepper samples varied between 2.08 – 34.91kJ and 7.04 – 62.76 kJkg -1 , respectively. The energy utilization and energy utilization ratio during the drying process ranged from 195.75 – 3013.21 Js -1 and 1.82 – 20.4%, respectively. The energy and exergy efficiencies varied between 15.6738.17% and 26% to 88%, respectively. The mean drying efficiency of the system ranged from 7.12 – 40.27%. The maximum electrical and thermal efficiencies of 23.86% and 93.03%, respectively were obtained. A waste energy ratio of 0.0827 0.1579 was obtained, whereas SI and IP values ranged between 1.137 ≤ SI ≤ 6.119 and 0.198 ≤ IP ≤0.583kW, respectively. There is certainly a wide range of improvement in the PV/T system as 12.1 – 18.4 % of the solar irradiance was consumed for drying. Prospects for improvement and recommendations for further studies were suggested.","PeriodicalId":281326,"journal":{"name":"Poljoprivredna tehnika","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Poljoprivredna tehnika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/POLJTEH1902056U","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a study carried out to investigate the performance of a hybrid photovoltaic/thermal crop dryer in hot humid region of Umuagwo-Ohaji in the South-east region of Nigeria, through energy and exergy analyses, drying, electrical and thermal efficiencies, energy utilization and energy utilization ratio, sustainability indicators such as waste energy ratio (WER), sustainability index (SI) and improvement potential (IP). Drying experiments were conducted at varying inlet air temperatures (50, 60 and 70 o C), airflow rates (1.14, 2.29 and 3.43 kgs -1 ) and slice thicknesses (10, 15 and 20 mm) on 500g batch size of red pepper slices during sunshine periods. Results obtained show that the total and specific energy consumption for drying a batch of sliced red pepper samples varied between 2.08 – 34.91kJ and 7.04 – 62.76 kJkg -1 , respectively. The energy utilization and energy utilization ratio during the drying process ranged from 195.75 – 3013.21 Js -1 and 1.82 – 20.4%, respectively. The energy and exergy efficiencies varied between 15.6738.17% and 26% to 88%, respectively. The mean drying efficiency of the system ranged from 7.12 – 40.27%. The maximum electrical and thermal efficiencies of 23.86% and 93.03%, respectively were obtained. A waste energy ratio of 0.0827 0.1579 was obtained, whereas SI and IP values ranged between 1.137 ≤ SI ≤ 6.119 and 0.198 ≤ IP ≤0.583kW, respectively. There is certainly a wide range of improvement in the PV/T system as 12.1 – 18.4 % of the solar irradiance was consumed for drying. Prospects for improvement and recommendations for further studies were suggested.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
光伏/热能混合作物干燥机在尼日利亚湿热地区的性能
本文介绍了一项研究,通过能源和用能分析、干燥、电气和热效率、能源利用和能源利用率、废物能比(WER)、可持续指数(SI)和改进潜力(IP)等可持续指标,调查了尼日利亚东南部Umuagwo-Ohaji湿热地区光伏/热混合作物干燥机的性能。以500g批量的红辣椒片为研究对象,在不同的进风温度(50、60和70℃)、不同的气流速率(1.14、2.29和3.43 kg -1)和不同的切片厚度(10、15和20 mm)下进行了晒干试验。结果表明,干燥一批红椒切片样品的总能量和比能量分别为2.08 ~ 34.91kJ和7.04 ~ 62.76 kJkg -1。干燥过程的能量利用率和能量利用率分别为195.75 ~ 3013.21 Js -1和1.82 ~ 20.4%。能量和火用效率分别在15.6738.17%和26% ~ 88%之间。系统的平均干燥效率为7.12% ~ 40.27%。电效率和热效率最高分别为23.86%和93.03%。得到的废能比为0.0827 0.1579,而SI和IP值分别为1.137≤SI≤6.119和0.198≤IP≤0.583kW。当然,PV/T系统的改进范围很广,因为12.1 - 18.4%的太阳辐照度被用于干燥。提出了改进的前景和进一步研究的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of soil saturated hydraulic conductivity at VFSTR campus using DRI method Hydraulic symbols - part four: Directional control valves Evaluation of uniformity and water conveyance efficiency of spray tube irrigation system Smart solution for safe and long-lasting operation of agricultural equipment Basic soil tillage of perennial plantations with a rotary shovel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1