A comparison of single fiber and routine EMG in normal subjects and patients with inflammatory myopathy.

R A Foote, W M O'Fallon, J R Daube
{"title":"A comparison of single fiber and routine EMG in normal subjects and patients with inflammatory myopathy.","authors":"R A Foote,&nbsp;W M O'Fallon,&nbsp;J R Daube","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We performed electromyography on the vastus lateralis muscle in 36 normal subjects and in 18 patients with inflammatory myopathy using a specially constructed dual electrode. This permitted simultaneous recording of a motor unit from a single fiber (SF) and standard sized electrode surface. We then correlated parameters of the SF potential (jitter, blocking, fiber density and duration) and the motor unit potential (MUP) (number of phases, duration) for different sites within the same individual. The mean values for the above parameters were correlated between individuals, and the group means were compared for the control and the inflammatory myopathy group.</p>","PeriodicalId":75651,"journal":{"name":"Bulletin of the Los Angeles neurological societies","volume":"43 2-4","pages":"95-103"},"PeriodicalIF":0.0000,"publicationDate":"1978-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Los Angeles neurological societies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We performed electromyography on the vastus lateralis muscle in 36 normal subjects and in 18 patients with inflammatory myopathy using a specially constructed dual electrode. This permitted simultaneous recording of a motor unit from a single fiber (SF) and standard sized electrode surface. We then correlated parameters of the SF potential (jitter, blocking, fiber density and duration) and the motor unit potential (MUP) (number of phases, duration) for different sites within the same individual. The mean values for the above parameters were correlated between individuals, and the group means were compared for the control and the inflammatory myopathy group.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正常人与炎性肌病患者单纤维肌电图与常规肌电图的比较。
我们使用特制的双电极对36名正常受试者和18名炎性肌病患者的股外侧肌进行了肌电图。这允许从单个纤维(SF)和标准尺寸的电极表面同时记录电机单元。然后,我们将同一个体内不同部位的SF电位(抖动、阻滞、纤维密度和持续时间)和运动单位电位(MUP)(相数、持续时间)的参数进行了关联。以上参数的平均值在个体之间具有相关性,并比较对照组和炎性肌病组的组均值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evoked potential instrumentation, methodology and theory. Brain generators of evoked potentials: the late (endogenous) components. Endogenous event-related potentials: prospective applications in neuropsychology and behavioral neurology. Clinical applications of visual evoked potentials in neurology. Somatosensory evoked potentials: applications in clinical neurology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1