Accuracy of estimates of contrast media concentration.

Revista interamericana de radiologia Pub Date : 1977-07-01
G L Wolf, D D Shaw
{"title":"Accuracy of estimates of contrast media concentration.","authors":"G L Wolf,&nbsp;D D Shaw","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An animal model was used to prepare 18 experimental roentgenograms with differing dilutions of Conray 400 in each renal pelvis. Fifty radiologists were asked to estimate the iodine concentrations after they had been shown examples with known iodine concentrations. It was found there was a great deal of variation in the ability of individual subjects to accurately estimate the iodine concentration present. When the urinary iodine was less than 25 mg/ml, contrast estimations became grossly unreliable. At higher concentrations, the average performance of the sixty subjects was fairly clos to observed densotimetric readings. This study demonstrates that the ability to estimate iodine concentration is similar to other perceptive abilities in demonstrating both thereshold sensitivity and a near normal distribution among observes of the ability to judge perceptable differences in contrast media density.</p>","PeriodicalId":76463,"journal":{"name":"Revista interamericana de radiologia","volume":"2 3","pages":"163-5"},"PeriodicalIF":0.0000,"publicationDate":"1977-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista interamericana de radiologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An animal model was used to prepare 18 experimental roentgenograms with differing dilutions of Conray 400 in each renal pelvis. Fifty radiologists were asked to estimate the iodine concentrations after they had been shown examples with known iodine concentrations. It was found there was a great deal of variation in the ability of individual subjects to accurately estimate the iodine concentration present. When the urinary iodine was less than 25 mg/ml, contrast estimations became grossly unreliable. At higher concentrations, the average performance of the sixty subjects was fairly clos to observed densotimetric readings. This study demonstrates that the ability to estimate iodine concentration is similar to other perceptive abilities in demonstrating both thereshold sensitivity and a near normal distribution among observes of the ability to judge perceptable differences in contrast media density.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
造影剂浓度估计的准确性。
采用动物模型制备了18张不同浓度Conray 400在每个肾盂内的实验x线图。在向50名放射科医生展示了已知碘浓度的样本后,他们被要求估计碘浓度。结果发现,个体受试者准确估计碘浓度的能力存在很大差异。当尿碘低于25mg /ml时,对比估计变得非常不可靠。在较高浓度下,60名受试者的平均表现相当接近观察到的密度计读数。这项研究表明,估计碘浓度的能力与其他感知能力相似,在判断造影剂密度的可感知差异的能力中,显示了阈值敏感性和接近正态分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
What's next? Cartilaginous tumors of the larynx. The sonographically solid appearing benign cystic teratoma. The role of biliary scintigraphy and ultrasonography in the diagnosis of cholecystitis. [Anatomy of the upper abdomen seen by real-time ultrasound].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1