{"title":"Typical Power Circuit Breaker Maintenance Considerations","authors":"D. K. Neitzel","doi":"10.1109/PPIC.2018.8502220","DOIUrl":null,"url":null,"abstract":"Electrical preventive maintenance and testing are some of the most important functions to be performed in order to maintain the reliability and integrity of electrical distribution systems, as well as for the protection of equipment and personnel. Preventive maintenance of electrical equipment, specifically with regard to power circuit breakers, is often overlooked or is performed infrequently or inadequately. This paper provides insights into the typical maintenance requirements for power circuit breakers, both low- and medium-voltage. Also addressed is the potential impact on the arc flash incident energy when maintenance is not performed. An unintentional time delay in the operation of a circuit breaker due to a sticky operating mechanism can cause the incident energy of an arc flash to rise, sometimes dramatically.","PeriodicalId":170960,"journal":{"name":"2018 IEEE IAS Pulp, Paper and Forest Industries Conference (PPFIC)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE IAS Pulp, Paper and Forest Industries Conference (PPFIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPIC.2018.8502220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Electrical preventive maintenance and testing are some of the most important functions to be performed in order to maintain the reliability and integrity of electrical distribution systems, as well as for the protection of equipment and personnel. Preventive maintenance of electrical equipment, specifically with regard to power circuit breakers, is often overlooked or is performed infrequently or inadequately. This paper provides insights into the typical maintenance requirements for power circuit breakers, both low- and medium-voltage. Also addressed is the potential impact on the arc flash incident energy when maintenance is not performed. An unintentional time delay in the operation of a circuit breaker due to a sticky operating mechanism can cause the incident energy of an arc flash to rise, sometimes dramatically.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
典型电源断路器维护注意事项
为了保持配电系统的可靠性和完整性,以及保护设备和人员,电气预防性维护和测试是必须执行的一些最重要的功能。电气设备的预防性维护,特别是关于电源断路器,经常被忽视或很少或不充分地进行。本文介绍了低压和中压电力断路器的典型维护要求。还讨论了在不进行维护时对电弧闪光入射能量的潜在影响。由于粘滞操作机构导致的断路器操作中的意外时间延迟可能导致电弧闪光的入射能量上升,有时甚至急剧上升。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Conference Committee Chairmen and Meritorious Award Winners Elements of Tuning a Power System Stabilizer for NERC Compliance A Phased Paper Machine Drive & Control System Upgrade Transformer Fuse Sizing - The NEC is not the Last Word The Secret to that Old Black Magic - Commutation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1