External Quality Assessment Scheme for Transfusion Transmissible Infections Among Blood Service Facilities in the Philippines, 2017

Kenneth Aristotle Punzalan, Rhoda Yu, Iza Mae Chamen
{"title":"External Quality Assessment Scheme for Transfusion Transmissible Infections Among Blood Service Facilities in the Philippines, 2017","authors":"Kenneth Aristotle Punzalan, Rhoda Yu, Iza Mae Chamen","doi":"10.21141/PJP.2018.012","DOIUrl":null,"url":null,"abstract":"The External Quality Assessment Scheme (EQAS) evaluates the performance of participating laboratories through an external agency by which known blinded samples are sent to participants for analysis, and their performance evaluated and monitored. The Transfusion Transmissible Infections – National Reference Laboratory provides an external quality assessment scheme for transfusion transmissible infections to blood service facilities in the Philippines with the aim of raising the standards of quality testing in infectious diseases in blood units and as a mandatory requirement in the licensing of laboratories. In the 2017 test event, 180 participants were given an EQAS panel composed of the HVHT4120 serology program and the MLRA415 malaria program. Results were submitted through an online informatics system managed by OneWorld Accuracy Canada using the ISO 13528:2008 Robust Statistics method (Huber’s Method). Results were analyzed and evaluated with the reference result of the NRL to which non-concordant results would be marked aberrant. From the 14,392 generated results from the HVHT4120 program and 885 generated results from the MLRA415 program, 51 (0.35%) results and 86 (9.72%) results were reported as aberrant respectively. The aberrant results reported were either due to random or systematic errors. Analyzed data from this test event are used for the continuous improvement of their competencies and the renewal of their license to operate as required by the Department of Health.","PeriodicalId":166708,"journal":{"name":"Philippine Journal of Pathology","volume":"103 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Philippine Journal of Pathology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21141/PJP.2018.012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The External Quality Assessment Scheme (EQAS) evaluates the performance of participating laboratories through an external agency by which known blinded samples are sent to participants for analysis, and their performance evaluated and monitored. The Transfusion Transmissible Infections – National Reference Laboratory provides an external quality assessment scheme for transfusion transmissible infections to blood service facilities in the Philippines with the aim of raising the standards of quality testing in infectious diseases in blood units and as a mandatory requirement in the licensing of laboratories. In the 2017 test event, 180 participants were given an EQAS panel composed of the HVHT4120 serology program and the MLRA415 malaria program. Results were submitted through an online informatics system managed by OneWorld Accuracy Canada using the ISO 13528:2008 Robust Statistics method (Huber’s Method). Results were analyzed and evaluated with the reference result of the NRL to which non-concordant results would be marked aberrant. From the 14,392 generated results from the HVHT4120 program and 885 generated results from the MLRA415 program, 51 (0.35%) results and 86 (9.72%) results were reported as aberrant respectively. The aberrant results reported were either due to random or systematic errors. Analyzed data from this test event are used for the continuous improvement of their competencies and the renewal of their license to operate as required by the Department of Health.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
2017年菲律宾血液服务机构输血传播感染外部质量评估方案
外部质量评估计划(EQAS)通过外部机构评估参与实验室的绩效,由外部机构将已知的盲法样本发送给参与者进行分析,并对其绩效进行评估和监测。输血传播感染——国家参考实验室为菲律宾的血液服务设施提供了一项输血传播感染的外部质量评估计划,目的是提高血液单位传染病的质量检测标准,并作为实验室许可的强制性要求。在2017年的测试活动中,180名参与者接受了由HVHT4120血清学项目和MLRA415疟疾项目组成的EQAS小组。使用ISO 13528:2008稳健统计方法(Huber’s method),通过寰宇一家准确性加拿大公司管理的在线信息系统提交结果。结果与NRL的参考结果进行分析和评价,不一致的结果为显著异常。在HVHT4120项目产生的14392个结果和MLRA415项目产生的885个结果中,分别有51个(0.35%)和86个(9.72%)结果报告为异常。报告的异常结果可能是由于随机误差或系统误差。从这次测试事件中分析的数据被用于不断提高他们的能力,并按照卫生部的要求更新他们的营业执照。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Defining the Terms of Reference of the PSP’s Committee on Academic and Research Pathology Mucosal Melanoma of the Male Urethra: A Case Report Correlation of Clinicopathologic Features of Filipino Primary Breast Cancer Patients with HER2 Subgroups Classified according to the ASCO/CAP 2018 Breast Cancer HER2 Testing Guidelines Needs Assessment for Establishment of Telepathology in the Philippines Ethical Concerns and Recommendations for Sharing Anatomic Pathology Images on Online Social Media Networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1