Interlinking Converter Operation in Hybrid Microgrid As a Tie-line

Shwetank Agrawal, B. Tyagi, Vishal Kumar, P. Sharma
{"title":"Interlinking Converter Operation in Hybrid Microgrid As a Tie-line","authors":"Shwetank Agrawal, B. Tyagi, Vishal Kumar, P. Sharma","doi":"10.1109/PEDES56012.2022.10080482","DOIUrl":null,"url":null,"abstract":"This paper studies the interlinking converter operation in the hybrid microgrid. Hierarchical control, i.e., primary and secondary, is implemented to control the hybrid microgrid. The primary control is performed using droop control for AC and DC Bus, whereas the secondary control is used to restore frequency and voltages of AC and DC section, respectively. The hybrid droop is used along with the low pass filter for the interlinking converter to balance the per unit power in AC and DC sections. The simulation study verifies that the hybrid microgrid can be analyzed as two area power system network connected with a tie line. The AC section is considered as one area and DC as another, whereas the interlinking converter is characterized as a tie line between the AC and DC sections.","PeriodicalId":161541,"journal":{"name":"2022 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDES56012.2022.10080482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper studies the interlinking converter operation in the hybrid microgrid. Hierarchical control, i.e., primary and secondary, is implemented to control the hybrid microgrid. The primary control is performed using droop control for AC and DC Bus, whereas the secondary control is used to restore frequency and voltages of AC and DC section, respectively. The hybrid droop is used along with the low pass filter for the interlinking converter to balance the per unit power in AC and DC sections. The simulation study verifies that the hybrid microgrid can be analyzed as two area power system network connected with a tie line. The AC section is considered as one area and DC as another, whereas the interlinking converter is characterized as a tie line between the AC and DC sections.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
混合微电网作为联络线的互连变流器运行
本文研究了混合微电网中互连变流器的运行问题。混合微电网的控制采用主、次层次控制。一次控制采用交直流母线的下垂控制,二次控制采用交直流段的频率恢复和电压恢复。混合下垂与低通滤波器一起用于互连转换器,以平衡交流和直流部分的单位功率。仿真研究验证了混合微电网可以分析为两条并线相连的区域电网。交流部分被认为是一个区域,直流部分被认为是另一个区域,而互连变换器的特征是交流和直流部分之间的联络线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analytical Series-PID controller design with Smith Predictor approach for analyzing and mitigating the Time Delay Cyber Attack (TDCA) A Novel Fault Detection Index in Smart Distribution System consisting Multi-Microgrids Combined SoC and SoE Estimation of Lithium-ion Battery using Multi-layer Feedforward Neural Network Fault Tolerance of the Neutral Point Clamped based Inverter Driven Nine Phase Induction Machine under Switch Fault Condition Sliding-Mode High-Gain Observer based Position Control for an Electro-Hydraulic Actuator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1